Samsung SONOACE R3 Manual de usuario

Busca en linea o descarga Manual de usuario para De medición, control y control Samsung SONOACE R3. Samsung SONOACE R3 User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 308
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente

Indice de contenidos

Pagina 1 - SONOACE R3

SAMSUNG MEDISON DIAGNOSTIC ULTRASOUND SYSTEMSONOACE R3User ManualVolume 1

Pagina 2

XMedical Electrical Equipment, Part 1-4: General Requirements for Safety - Collateral Standard: Programmable Electrical Medical Systems [IEC 60601-1-

Pagina 3

User Manual4-12  2D Mode SoftmenuFollowing items are displayed on soft menu in 2D mode. Select the item and adjust the value with the Softmenu button

Pagina 4

Chapter 4 Diagnosis Modes4-13M ModeBy drawing the M line across a desired area within the 2D image, you can view changes over time.This is useful for

Pagina 5

User Manual4-14  M Mode MenuFollowing items are displayed on menu when you press the Menu dial-button in M mode. Select the item and adjust the value

Pagina 6

Chapter 4 Diagnosis Modes4-15Color Doppler ModeThis mode displays the colored blood ow pattern of the ROI (Region of Interest) within the 2D image.

Pagina 7

User Manual4-16Use the Change button to adjust the position and size of the ROI box. Each time you press the Change button, the status of the ROI box

Pagina 8

Chapter 4 Diagnosis Modes4-17 Color modeSet the contents that are displayed in color. Select Vel., Power, Var., or VelVar. with the Menu dial-button

Pagina 9 - Safety Requirements

User Manual4-18▶Tag Width: It is available when Color Tag is on. Use the Menu dial-button to select the range of tags, from between 8 - 256. Tag Widt

Pagina 10 - Declarations:

Chapter 4 Diagnosis Modes4-19Power Doppler ModeThis mode displays the color intensity of blood ow within the ROI in the 2D image. It is appropriate

Pagina 11 - Precautions for Use

User Manual4-20 ROI BoxROI stands for Region Of Interest. In Power Doppler Mode, ROI indicates the area of the 2D image where color (blood ow) infor

Pagina 12

Chapter 4 Diagnosis Modes4-21PW Spectral Doppler ModePW stands for Pulse Wave. PW Spectral Doppler Mode gives information on the speed of blood flow

Pagina 13 - Revision History

Precautions for UseYou should be familiar with all of these areas before attempting to use this manual or your ultrasound system. Please keep this

Pagina 14

User Manual4-22 Sample VolumeWhen Sample Volume is positioned over the blood flow in a 2D image, the Doppler Spectrum is displayed. Information on th

Pagina 15 - Table of Contents – Volume 1

Chapter 4 Diagnosis Modes4-23[Figure 4.8 HPRF]NOTE: HPRF cannot be activated in Simultaneous Mode. Also, HPRF cannot be activated if the PRF value X

Pagina 16 - Chapter4 Diagnosis Modes

User Manual4-24 Spectrum Ehc.Spectrum Ehc stands for Spectrum Enhancement. This functionis used to compensate the signal of low gain Spectral Doppler

Pagina 17 - ** Reference Manual

Chapter 4 Diagnosis Modes4-25  PW Spectral Doppler Mode Soft MenuFollowing items are displayed on soft menu in PW Spectral Doppler mode. Select the

Pagina 18

User Manual4-26 Combined Modes2D/C/PW ModeColor Doppler Mode and PW Spectral Doppler Mode are displayed simultaneously. Press the PW button on the co

Pagina 19 - Chapter1

Chapter 4 Diagnosis Modes4-27  Changing Combined Mode Format Changing Active ImagePress the Set button. The currently active image mode, such as ‘P

Pagina 20

User Manual4-28 Dual ModeThe multi-image viewing function is only available when the images and conditions on both sides are identical. The current a

Pagina 21 - Purpose of Use

Chapter 4 Diagnosis Modes4-29 3D Mode3DThe 3D Mode displays tissues or objects in the human body as three-dimensional images inste-ad of two-dimensi

Pagina 22 - Safety Signs

User Manual4-30Acquiring a 3D Image The following explains how to acquire a 3D image. 1. Press the 3D key on the keyboard.2. The ROI box appears. Set

Pagina 23 - Chapter 1 Safety

Chapter 4 Diagnosis Modes4-313D View3D images can be seen through the 3D View application.[Figure 4.9 3D View]  Viewing a 3D Image ▶ Select the menu

Pagina 24

DANGER: Describes precautions necessary to prevent user hazards of great urgency. Ignoring a DANGER warning will risk life-threatening injury.WARNING:

Pagina 25 - Electrical Safety

User Manual4-32  3D Image Optimization Threshold (Low, High) AdjustmentAdjust the slide bar of the threshold using the Trackball and the Set button.

Pagina 26

Chapter 4 Diagnosis Modes4-33[Figure 4.10 Soft Menu - Rotation Mode]Tips!Other ways to rotate the image1. The ROT slide bar at the bottom of the scr

Pagina 27

User Manual4-34 MagnicationTo magnify or reduce the image size, enter Magnication mode by pressing the Magnication button, and move the Trackball

Pagina 28 -  Guidance and manufacturer

Chapter 4 Diagnosis Modes4-35 Multi planar Press Multi planar, and 3D multiplanar screen appears. Shows volume data in cross-section images of Coron

Pagina 29 - Peripherals

User Manual4-36Use X/Y/Z slide on the screen to rotate reference plane.AYYZXXYZZXCB[Figure 4.17 The standard coordinates systems of Multi-planar]YXZRe

Pagina 30

Chapter 5Measurements and CalculationsChapter5 Measurements and CalculationsMeasurement Accuracy ...5-3Causes of Me

Pagina 31

Chapter 5Report ... 5-51Viewing Report ...

Pagina 32

Chapter 5 Measurements and Calculations5-3 Measurement AccuracyMeasurement values can vary, depending on the nature of the ultrasound, the body’s re

Pagina 33

User Manual5-4  Ultrasound VelocityXThe velocity of ultrasound used during measurement is usually 1,540 m/s on average.XThe velocity of ultrasound

Pagina 34

Chapter 5 Measurements and Calculations5-5Optimization of Measurement Accuracy  2D ModeXResolution is in proportion to the frequency of the probe.

Pagina 35 - Mechanical Safety

Revision HistoryThe revision history of this manual is as follows.VERSION DATE NOTEv2.01.03-00 2015.04.14Initial ReleaseSystem Upgrades and Manual Se

Pagina 36 - Biological Safety

User Manual5-6  Color/Power Doppler ModeXA protocol is not specied for images in Color Doppler Mode or Power Doppler Mode. Therefore, the same limi

Pagina 37 -  Direct Controls

Chapter 5 Measurements and Calculations5-7Measurement Accuracy TableThe following tables show the accuracy of the measurements available using the pr

Pagina 38 -  Receiver Controls

User Manual5-8  PW Spectral Doppler ModeDoppler MeasurementSystem Tolerance(whichever is greater)Methodology Range(1)Velocity < ± 15% Phantom 0.

Pagina 39 -  Output Display Features

Chapter 5 Measurements and Calculations5-9 Basic MeasurementsPress the Caliper button on the control panel. NOTE: Take basic measurements of distanc

Pagina 40 - Thermal Index (TI) Display

User Manual5-10  Basic Measurement OperationsThe following is the information on common button operations for basic measurements:[Figure 5.1 Basic Me

Pagina 41

Chapter 5 Measurements and Calculations5-11Distance Measurement  2D Distance (Line) This is a basic measurement that is available in all diagnosis m

Pagina 42 -  Color and Power Controls

User Manual5-12  M DistanceThis is a basic measurement that is available in M Mode only. You can specify two points in an M image and measure the dis

Pagina 43

Chapter 5 Measurements and Calculations5-13The equations used for D Velocity measurement are as follows:  Doppler Velocity (A/B)This is a basic meas

Pagina 44 -  Related Guidance Documents

User Manual5-14  Doppler TraceThis is a basic measurement that is available in Spectral Doppler Mode only. You can specify a point in a Spectral Dopp

Pagina 45 - -(0.23 alf)

Chapter 5 Measurements and Calculations5-15Circumference and Area Measurement  2D EllipseThis is a basic measurement that is available in all diagn

Pagina 47 - Systematic Uncertainties

User Manual5-16  2D TraceThis is a basic measurement that is available in all diagnosis modes. You can measure the circumference and area of an irreg

Pagina 48 -  Training

Chapter 5 Measurements and Calculations5-17Volume Measurement  3 DistanceThis is a basic measurement that is available in all diagnosis modes. You c

Pagina 49 - Environmental Protection

User Manual5-18  Distance + EllipseThis is a basic measurement that is available in all diagnosis modes. You can measure the volume of an ob-ject in

Pagina 50

Chapter 5 Measurements and Calculations5-19Angle Measurement  2D Angle This is a basic measurement that is available in all diagnosis modes. Specify

Pagina 51 - Introduction

User Manual5-20  2D Hip Joint This is a basic measurement that is available in all diagnosis modes. You can measure the angle of two straight lines t

Pagina 52

Chapter 5 Measurements and Calculations5-21 Calculations by Application Press the Calc button on the control panel.Things to note  Before Taking Me

Pagina 53 - Specications

User Manual5-22  Measurement OperationsThe following gives information on the common button operations for measurements: Select/Change ApplicationUs

Pagina 54

Chapter 5 Measurements and Calculations5-23  Soft Menu[Figure 5.2 Calculations by Application – Soft Menu] Menu A/Menu BWhen there are a lot of mea

Pagina 55 - Product Conguration

User Manual5-24Common Measurement MethodsThis section provides information on the common measurement methods used for applications.  Measurements in

Pagina 56

Chapter 5 Measurements and Calculations5-25Tips!Things to consider for Doppler Spectrum Auto TraceThe state of a Doppler spectrum may affect measureme

Pagina 57 -  Adjusting Brightness

Table of Contents 15Table of Contents – Volume 1Chapter1 SafetyPurpose of Use ...

Pagina 58 - [Figure 2.2 Control Panel]

User Manual5-26 Volume Flow MeasurementSelect Volume Flow in the Measurement menu. Volume Flow allows you to measure and calculate an area or distance

Pagina 59 -  Control Panel Map

Chapter 5 Measurements and Calculations5-27  Heart Rate Measurement HR (Heart Rate)You can calculate heart rates for a certain period of time.1. Se

Pagina 60 - [Figure 2.3 Soft menu button]

User Manual5-28OB Calculations  Before Obtaining OB CalculationsSet GA Equation, GA Table and OB Measurement menus. The user can manually write, back

Pagina 61 - [Figure 2.4 keyboards]

Chapter 5 Measurements and Calculations5-29Measurement Menu Item Mode Method UnitFetal BiometryGS All Distance cm, mmCRL All Distance cm, mmYS All Di

Pagina 62 - Measurement function keys

User Manual5-30Measurement Menu Item Mode Method UnitFetal OthersFoot All Distance cm, mmEar All Distance cm, mmMP All Distance cm, mmAFIAll All Dista

Pagina 63 - [Figure 2.5 Console]

Chapter 5 Measurements and Calculations5-31  Automatic Calculation Some items in the measurement menu are automatically calculated based on measurem

Pagina 64 - [Figure 2.6 Rear Panel]

User Manual5-32  AFI (Amniotic Fluid Index)This measures the amniotic uid index. Measurements are performed by dividing the pregnant woman’s abdomen

Pagina 65 -  Probe Holder

Chapter 5 Measurements and Calculations5-33GYN CalculationsThe measurement method for each item is the same as for basic measurement. Measured items

Pagina 66 - Peripheral Devices

User Manual5-34Measurement Menu Item Mode Method UnitRt./Lt. Follicle 1 ~ 12 All Distance cm, mmRt./Lt. Ovarian AAuto Trace PW Doppler Spectrum TraceL

Pagina 67 - Foot Switch

Chapter 5 Measurements and Calculations5-35Cardiac CalculationsNOTE: XCardiac measurement is an optional item for SONOACE R3. XSince the cardiac bl

Pagina 68 - [Figure 2.9 Probe Connector]

User Manual16Chapter3 Starting Diagnosis Power Supply ...

Pagina 69 - [Figure 2.10 SONOACE R3 Cart]

User Manual5-36Measurement Menu Item Mode Method Unit2D MeasureAll All Continuous cm, mmIVSd All Distance cm, mmIVSs All Distance cm, mmLVDd All Dist

Pagina 70 - Accessory

Chapter 5 Measurements and Calculations5-37Measurement Menu Item Mode Method UnitMV (M)All Points M ContinuousD-E M Distance cm, mmE-F Slope M Velo

Pagina 71 - Chapter 2 Introduction

User Manual5-38Measurement Menu Item Mode Method UnitLVOT DopplerAuto Trace PWDoppler Spectrum TraceLimited Trace PWDoppler Spectrum TraceManual Trace

Pagina 72

Chapter 5 Measurements and Calculations5-39Measurement Menu Item Mode Method UnitTV InowLimited Trace PWDoppler Spectrum TraceManual Trace PWDoppler

Pagina 73 - Starting Diagnosis

User Manual5-40Measurement Menu Item Mode Method UnitPV RegurgAuto Trace PWDoppler Spectrum TraceLimited Trace PWDoppler Spectrum TraceManual Trace PW

Pagina 74

Chapter 5 Measurements and Calculations5-41Measurement Menu Item Mode Method UnitQp:QsSys. VTI PW Distance cm, mmSys. HR PW Heart Rate bpmSys. Dia

Pagina 75 - Power Supply

User Manual5-42Vascular Calculations It is convenient to calculate each measurement value on the Spectral Doppler image.The measurement method for eac

Pagina 76 - [Figure 3.1 Application]

Chapter 5 Measurements and Calculations5-43Measurement Menu Item Mode Method UnitRt./ Lt. SubclavianAuto Trace PW Doppler Spectrum TraceLimited Trace

Pagina 77 - Application

User Manual5-44Urology CalculationsThe measurement methods of each menu vary with the Volume Method set at Setup > Measure > Urology. The measur

Pagina 78 - Editing BodyMarker

Chapter 5 Measurements and Calculations5-45Measurement Menu Item Mode Method UnitProstate Vol.All AllCalculated after distance measurementml1st Dia.

Pagina 79 -  Save BodyMarkers

Table of Contents 17Chapter5 Measurements and CalculationsMeasurement Accuracy ...

Pagina 80 - Calc Sequence

User Manual5-46 EllipsoidVolume is calculated using the Main diameter and Beside Diameter values.Measurement Menu Item Mode Method UnitVolume FlowAut

Pagina 81 - Patient Information

Chapter 5 Measurements and Calculations5-47 Sum of 20 DisksMeasure the prostate circumference and then use the trackball and the Set button to measu

Pagina 82 - Registering a New Patient

User Manual5-48Fetal Echo CalculationsThe measurement method for each item is the same as for basic measurement. In addition, measurement items are si

Pagina 83 - Calculating EDD

Chapter 5 Measurements and Calculations5-49Measurement Menu Item Mode Method Unit2D EchoAsc. Aorta Distance Doppler Spectrum Trace cm, mmMPA Distan

Pagina 84

User Manual5-50Measurement Menu Item Mode Method UnitIVC Same as above Same as aboveDuct. Ven Same as above Same as aboveAsc. Aorta Same as above Same

Pagina 85 - [Figure 3.5 Search]

Chapter 5 Measurements and Calculations5-51 ReportCheck the measurement and calculation results in the report of each application. ▶ Press the Report

Pagina 86

User Manual5-52Viewing Report▶ The measurement and calculation items and their values are displayed. ▶ When the report screen has more than two pages,

Pagina 87

Chapter 5 Measurements and Calculations5-53  Open Line TransferTransfer the report to another computer or printer. Press the Open Line Transfer on t

Pagina 88 - Modifying Patient Information

User Manual5-54Graph Function▶ This function is used to display the GA values such as BPD, HC, AC and FL, allowing the user to diagnose fetal growth.

Pagina 89 - Diagnosis Modes

SAMSUNG MEDISON DIAGNOSTIC ULTRASOUND SYSTEMSONOACE R3User ManualVolume 2

Pagina 92 - Basic Use

SAMSUNG MEDISON DIAGNOSTIC ULTRASOUND SYSTEMVersion 2.01EnglishSONOACE R3User Manual

Pagina 94 - Harmonic

Table of Contents 5Table of Contents – Volume 2Chapter6 Image ManagementCINE/LOOP ...

Pagina 95 - [Figure 4.1 2D Mode]

User Manual6Setting DICOM (Optional)...7-

Pagina 96 -  2D Mode Menu

Table of Contents 7Chapter9 ProbesProbes ...

Pagina 98 - [Figure 4.2 2D Post]

Chapter 6Image ManagementChapter6 Image ManagementCINE/LOOP ... 6-3Annotating Images ...

Pagina 100 -  2D Mode Softmenu

Chapter 6 Image Managemen6-3 CINE/LOOPImages are automatically saved in the memory during scanning. The saved images can be useful when a pa-tient is

Pagina 101 - [Figure 4.4 M Mode]

Chapter1Purpose of Use ... 1-3Contraindications ...

Pagina 102 -  M Mode Soft Menu

User Manual6-4 How to Review ImagesUse the trackball on the control panel. You can search for saved images in chronological order by rotating the Trac

Pagina 103 - Color Doppler Mode

Chapter 6 Image Managemen6-5 Cine SaveUse the Softmenu button [4]. Save the Cine whole Cine images. NOTE: XWhen saving a Cine image, the current ti

Pagina 104 -  C Mode Menu

User Manual6-6 Annotating Images TextYou can enter comments or text over an image. This function can be useful when the diagnosis area is dier-entia

Pagina 105 - Chapter 4 Diagnosis Modes

Chapter 6 Image Managemen6-7 AutotextThis function allows you to enter text automatically by using an abbreviation. In this way, you can enter text e

Pagina 106 -  C Mode Softmenu

User Manual6-8BodyMarker You can place a BodyMarker over an image. This function can be useful when the diagnosis area is dierenti-ated or displayed.

Pagina 107 - Power Doppler Mode

Chapter 6 Image Managemen6-9 Entering BodyMarker 1. Press the BodyMarker key on the keyboards, BodyMarkers will appear on the user information area.

Pagina 108 -  PD Mode Soft Menu

User Manual6-10Indicator You can place an Indicator over an image. This function can be useful when the diagnosis area is dierentiat-ed or displayed.

Pagina 109 - PW Spectral Doppler Mode

Chapter 6 Image Managemen6-11 Deleting Indicator Press the Clear button on the control panel and all Indicators displayed on the screen will be delet

Pagina 110 - Sample Volume

User Manual6-12 Saving and Transferring ImagesSaving Images WARNING: You must enter the patient ID because all images are saved according to patient

Pagina 111 - [Figure 4.8 HPRF]

Chapter 6 Image Managemen6-13Transferring Images Send images using DICOM. For more information on the DICOM server settings and DICOM operation, see

Pagina 114 - Combined Modes

User Manual6-14 Printing and Recording ImagesPrinting ImagesPress the Print button on the control panel to print out a scanned image using a printer.

Pagina 115 - Changing Menu

Chapter 6 Image Managemen6-15 SONOVIEWSONOVIEW is an integrated image management program in SONOACE R3. It allows you to save, view and de-lete image

Pagina 116 - Dual Mode

User Manual6-16Exam ViewNOTE: If you select an icon on the Exam View screen, the name of icon will be displayed. Starting Exam ViewPress Exam Search

Pagina 117 - 3D Mode

Chapter 6 Image Managemen6-17 Selecting Exam Use the trackball and the Set button to select an examination. To cancel the exam selection, press the S

Pagina 118 - Acquiring a 3D Image

User Manual6-18 Exam Export Multiple exams can be selected and exported simultaneously.1. Select exam(s) and press Export to bring up the Export windo

Pagina 119 - [Figure 4.9 3D View]

Chapter 6 Image Managemen6-19Tips!When selecting 2D Cine, an image and a video are saved together. The saved AVI file (*.avi) can be played by a video

Pagina 120 -  3D Image Optimization

User Manual6-20 Using USB Flash MemoryUSB ash memory can be connected to the USB port on the left side or the rear panel. Only one ash memory can b

Pagina 121 - Position

Chapter 6 Image Managemen6-21[Figure 6.9 DICOM Send] Printing Exam This function uses printer(s) on the DICOM network. DICOM Print will not work if t

Pagina 122 - Cut Mode

User Manual6-22Exam ReviewSaved images can be managed using measurement, printing, sending and many other functions. [Figure 6.10 Exam Review]NOTE: If

Pagina 123 - [Figure 4.16 Multi planar]

Chapter 6 Image Managemen6-23 Close ExamCloses the current exam(s). Exam SearchThe Exam View screen appears. You can browse through exams to select,

Pagina 124 - User Manual

Chapter 1 Safety 1-3 Purpose of UseThe SONOACE R3 Diagnostic Ultrasound System and transducers are intended for diagnostic ultrasound imaging and 

Pagina 125 - Calculations

User Manual6-24 PrintingThis function prints images or simple reports.1. Press Print from the Exam Review screen. 2. Select settings from the Print wi

Pagina 126 - Chapter 5

Chapter 6 Image Managemen6-25 DICOM Printing (Optional)This function uses DICOM to print selected images. This button is deactivated for products tha

Pagina 127 - Measurement Accuracy

User Manual6-26 DeleteSelect image(s) and press Delete Image on the Exam Review screen. To delete many images at once, use Trackball and Set button du

Pagina 128 -  Human Error

Chapter 6 Image Managemen6-274. Use the trackball to move the cursor to another location and press the Set button to set the end point. ▶ Press the C

Pagina 130 -  Cursor Position

Chapter 7UtilitiesChapter7 UtilitiesSetting System ... 7-3General ...

Pagina 131 - Measurement Accuracy Table

Chapter 7Setting Option ...7-34Setting Peripheral Devices ...7-35Information ..

Pagina 132 -  PW Spectral Doppler Mode

Chapter 7 Utilities7-3 Setting System This mode is used for system settings. It does not aect image output. The setup may be modied depending on s

Pagina 133 - [Table 5.1 Basic Measurement]

User Manual7-4 InstitutionEnter the name of the hospital/institution. LanguageThis sets the language to be used. English, Deutsch, Français, Italian

Pagina 134 - Finish Basic Measurements

Chapter 7 Utilities7-5Tips!How to set the date and time.[Figure 7.2 Date & Time Setup]XClick Set in the Title tab of System menu.XSet the Date/

Pagina 135 - Distance Measurement

User Manual1-4 Safety SignsPlease read this chapter before using the Samsung Medison ultrasound system. It is relevant to the ultrasound system, the

Pagina 136 -  Doppler Velocity

User Manual7-6Tips!How to edit the Autotext Set.Click Edit on the screen. The Autotext Table Edit Table window will be appeared. To add a new abbrevia

Pagina 137 -  Doppler Velocity (A/B)

Chapter 7 Utilities7-7Display To set the information about images and related data, select the Display tab in the System menu. Auto FreezeAfter the

Pagina 138 -  Doppler Trace

User Manual7-8 Display GenderThis sets whether or not the gender of the patient is displayed. If ‘On’ is selected, the patient’s gender is shown. Si

Pagina 139 -  2D Ellipse

Chapter 7 Utilities7-9Misc.Select the Misc. tab in the System menu.[Figure 7.5 System Setup – Misc.] OB Measure Shortcut KeySelect On to start a des

Pagina 140 -  2D Trace

User Manual7-10 ThumbnailTo use thumbnail list, set this item as ‘On’. Thumbnails of saved images are showed up on the right side of the screen.  Se

Pagina 141 - Volume Measurement

Chapter 7 Utilities7-11 Setting Measurements Select Measure in the Setup menu to set up measurement functions.1. Press the Setup key on the keyboard

Pagina 142 -  Distance + Ellipse

User Manual7-12 GeneralSelect General tab. Measure Item Display CountSelect the number of measurement items to be between 1 and 4. If you select ‘Hid

Pagina 143 - Angle Measurement

Chapter 7 Utilities7-13 Doppler Select the Doppler tab in the General tab. [Figure 7.7 Measure - Doppler] Y-Axis UnitThis sets the vertical (Y) axis

Pagina 144 -  2D Hip Joint

User Manual7-14 Mean Trace This menu species the use of Mean Trace Line on the screen for Auto trace/Limited trace.Tips!How to change Doppler settin

Pagina 145 - Things to note

Chapter 7 Utilities7-15 ReportSelect the Report tab in the General tab.Select items to mark the header on the report. The header will be shown only t

Pagina 146 -  Measurement Operations

Chapter 1 Safety 1-5Symbols Description Symbols DescriptionPower on Microphone PortPower o Probe portPower ON for part of the productProtected agai

Pagina 147 -  Soft Menu

User Manual7-16OBSelect the OB tab in the Measure menu.[Figure 7.10 Measure – OB] Display SD ValueThis menu sets whether SD (Standard Deviation) is d

Pagina 148 - Common Measurement Methods

Chapter 7 Utilities7-17▶Auxiliary Unit: This sets the auxiliary unit of fetal weight measurement. Unit sets the available auxiliary unit. For instan

Pagina 149

User Manual7-18 GraphThe user can select graphs to mark on the OB report or print. Press Graph button and select items. After selecting/deselecting a

Pagina 150 -  Stenosis Measurement

Chapter 7 Utilities7-19 Backup/Restore▶BackupIf you want to back up a new user preset to Mo Media, Flash Memory or a HDD, press Backup/Restore on t

Pagina 151 -  Heart Rate Measurement

User Manual7-20Fetal Echo Select the Fetal Echo tab in the Measure menu.[Figure 7.14 Measurement Setting– Fetal Echo]During obstetric measurement, Fet

Pagina 152 - OB Calculations

Chapter 7 Utilities7-21Cardiac Select the Cardiac tab in the Measure menu.  2D Circumference and Area MethodSelect either the ‘Ellipse’ or ‘Trace’ c

Pagina 153

User Manual7-22Urology Measurement SetupSelect the Urology tab in the Measure menu. [Figure 7.16 Measure– Urology] Volume Method▶3 Distance: The vol

Pagina 154

Chapter 7 Utilities7-23NOTE: 3 Distances: A = 1st Dia. ; B = 2nd Dia. ; C = 3rd Dia. The default factor value (F) is ‘0.5’. If it is changed, a value

Pagina 155 -  Automatic Calculation

User Manual7-24Vascular Select the Vascular tab in the Measure menu. You can set the peak velocity used in the calculation of the ‘A/B Ratio’ and ‘ICA

Pagina 156 -  AFI (Amniotic Fluid Index)

Chapter 7 Utilities7-25 Setting DICOM (Optional)Select the DICOM tab in the Setup menu. This function is used to set up the DICOM server and other D

Pagina 157 - GYN Calculations

User Manual1-6Labels Phrases containing the words ‘warning’ and/or ‘caution’ are displayed on the product’s surface in order to protect it.

Pagina 158

User Manual7-26Setting DICOM InformationEnter the DICOM information for the product in use. For automatic DICOM transmission, select ‘Acquisition in P

Pagina 159 - Cardiac Calculations

Chapter 7 Utilities7-27 ServiceSelect the kind of server to use. The supported DICOM servers are Store, Print, and Worklist. AliasEnter the name of

Pagina 160

User Manual7-28[Figure 7.19 DICOM Configuration-Store] Print Server InformationSelect PRINT under Services. Congure the Print Service using DICOM. NO

Pagina 161

Chapter 7 Utilities7-29 Border DensitySpecify the border density of an image to print. Select Black or White. Empty DensitySpecify the background c

Pagina 162

User Manual7-30 Conguration InfoSpecify the unique value for a printer. Please refer to the DICOM Conformance Statement for the printer.[Figure 7.20

Pagina 163

Chapter 7 Utilities7-31 Scheduled Station AE TitleSets the range of AE Title to fetch from the hospital’s Worklist server.▶All: Obtains the list of

Pagina 164

User Manual7-32Editing the DICOM Server Information Click Edit in the setting DICOM window to edit the server information already entered.Deleting DIC

Pagina 165

Chapter 7 Utilities7-33 DICOM LogView, copy, or delete the DICOM log les.▶View Selected File: Select the log le from ‘Select log les to copy’ an

Pagina 166 - Vascular Calculations

User Manual7-34 Setting OptionThe S/W serial No information of the system is shown in this window. You can select/cancel S/W options. A user cannot m

Pagina 167

Chapter 7 Utilities7-35 Setting Peripheral DevicesThe following describes how to set up the video output type, video input type, printer, foot switc

Pagina 168 - Urology Calculations

Chapter 1 Safety 1-7 Electrical SafetyThis equipment is categorized as a Class I device with Type BF applied parts.CAUTION: As for US requirement,

Pagina 169 - 3 Distance * Factor

User Manual7-36 Printer 1Select a printer to use. After connecting a USB printer to the USB port of the system, select the printer type on the screen

Pagina 170 - Ellipsoid

Chapter 7 Utilities7-37 InformationThe information menu displays information about the system S/W version. Select the Information tab in the Setup me

Pagina 171 - Sum of 20 Disks

User Manual7-38 Utility Press Utility key on the keyboard. The Utility menu appears at the left side of the screen. You can select a menu with the Men

Pagina 172 - Fetal Echo Calculations

Chapter 7 Utilities7-39 Editing Biopsy guide lineNOTE: XNote that the Biopsy Guide Line cannot be edited when the Trapezoidal function is in use for

Pagina 173

User Manual7-40 Starting and Finishing BiopsyNOTE: The biopsy guideline must be adjusted before a biopsy can be performed.1. Select On in the Biopsy m

Pagina 174

Chapter 7 Utilities7-41Monitor CalibrationSelect Monitor Calibration in Utility menu. Set the color or brightness of the image. [Figure 7.28 Monitor

Pagina 175

User Manual7-42PresetPreset allows the user to adjust Image Settings and select a Setting to apply to the system.Select Preset in the utility menu.[Fi

Pagina 176 - Exporting Report

Chapter 7 Utilities7-43 HistogramShows the brightness level of the selected area in a histogram.1. Select Histogram in the Miscellaneous menu.2. Spec

Pagina 178 - Graph Function

Chapter 8MaintenanceChapter8 MaintenanceOperating Environment ...8-3System Maintenance ...

Pagina 179

User Manual1-8CAUTION: XThe system has been designed for 100-120VAC and 200-240VAC; you should select the input voltage of printer and VCR. Prior to

Pagina 181

Chapter 8 Maintenance8-3 Operating EnvironmentWhen installing the console, please consider the following:CAUTION: Placing the system near generators

Pagina 182

User Manual8-4 System MaintenanceCleaning and disinfections Using inappropriate detergent or disinfectant may damage the product. Please read the fol

Pagina 183 - Table of Contents – Volume 2

Chapter 8 Maintenance8-5 DisinfectionsCAUTION: Use only recommended disinfectants on system surfaces.A disinfectant qualified by the FDA 510 (k) proc

Pagina 184 - Chapter8 Maintenance

User Manual8-6 Data MaintenanceCAUTION: You may lose information files on user settings or patients, because of shock on the product or internal error

Pagina 185 - Chapter9 Probes

Chapter 8 Maintenance8-7SoftwareChanges can be made to the product software to make it suitable for a particular user’s environment. Howev-er, these

Pagina 187 - Image Management

Chapter 9ProbesChapter9 ProbesProbes ...9-3Ultrasound transmission Gel ...

Pagina 189 - [Figure 6.1 Reviewing Images]

Chapter 9 Probes9-3 ProbesThe probe is a device that sends and receives ultrasound for acquiring image data. It is also called a Transducer or Scanhe

Pagina 190 - How to Review Images

Chapter 1 Safety 1-9ESDElectrostatic discharge (ESD), commonly referred to as a static shock, is a naturally occurring phenomenon. ESD is most preva

Pagina 191 - Speed (%)

User Manual9-4NOTE: XBesides, user can have or select own preset between User1-5. XRefer to ‘Chapter3. Starting Diagnosis’ for how to set probe and

Pagina 192 - [Figure 6.2 Text Mode]

Chapter 9 Probes9-5Probe Application HAR PI SCI DMR+ Q Scan ECGL5-12/60Breast x x x x O xSmall Parts x x x x O xVascular x x x x O xMusculoskeletal x

Pagina 193 - Exiting Text Mode

User Manual9-6Probe Application CM TDI PD TDW CWC2-4/20Abdomen x x O x xCardiac O x O x xC2-5Abdomen x x O x xOB x x O x xGynecology x x O x xFetal He

Pagina 194 - [Figure 6.4 BodyMarker Mode]

Chapter 9 Probes9-7Probe Application CM TDI PD TDW CWLE5-12Breast x x O x xSmall Parts x x O x xVascular x x O x xMusculoskeletal x x O x xLN5-12Brea

Pagina 195 - Exiting BodyMarker Mode

User Manual9-8 TI TableTI (Thermal Index) is displayed on the title of the screen and shows the estimate of the temperature increase in specic body

Pagina 196 - [Figure 6.5 Indicator Mode]

Chapter 9 Probes9-9Ultrasound transmission GelUsing an inappropriate ultrasound gel may damage the probe. For proper transmission of the acoustic bea

Pagina 197 - Exiting Indicator Mode

User Manual9-10 Installing the Sheath1. Use sterile gloves.2. Unpack the sheath and ll it with acoustic coupling gel.3. Insert the probe into the

Pagina 198 - Saving Images

Chapter 9 Probes9-11 Use and Infection Control of the ProbeWARNING: No neurosurgical treatments or examinations should be carried out on a patient wi

Pagina 199 - Transferring Images

User Manual9-12Cleaning and Disinfecting the ProbeWARNING: XAlways use protective eyewear and gloves when cleaning and disinfecting probes.XInspect

Pagina 200 - Recording Images

Chapter 9 Probes9-13NamesDisinfectantsCidex OPA 2), 3), 6), 7)Cidex Plus 2), 7)Metricide 2), 7)Omnicide (28)Omnicide 14NSOmnicide - FG2NucleanWavicid

Pagina 201 - [Figure 6.6 SONOVIEW]

User Manual1-10EMC The testing for EMC(ElectroMagnetic Compatibility) of this system has been performed according to the international standard for EM

Pagina 202 - [Figure 6.7 Exam View]

User Manual9-14NamesDisinfectants CleanerVirkonSporoxSporox IIGigaseptGigasept AF 3)Gigasept FFHibitanePeraSaveEnzolAlkazymeCidezymeKlenzymeIsopropyl

Pagina 203 - Deleting Exam

Chapter 9 Probes9-15NamesCleaner GelEthanol 75%MetrizymeMcKessonNatural ImageAquasonics 100 3)GE Ultrasound Contact GelClear ImageKendallScanWaveleng

Pagina 204 - [Figure 6.8 Exam Export]

User Manual9-16Tips!Symbols (1) Compatible but no EPA Registration (2) FDA 510 (k) cleared (3) Has CE mark (4) Discontinued (5) Under D

Pagina 205 - Exam Restore

Chapter 9 Probes9-17Following is information about manufacturer (or Distributor) of Detergent, Disinfectant, and Ultrasound Gel. Product Manufacturer

Pagina 206 - Sending Exam

User Manual9-18 CleaningCleaning is an important procedure that is carried out before disinfecting the probe. The probe must be cleaned after each use

Pagina 207 - [Figure 6.9 DICOM Send]

Chapter 9 Probes9-19 DisinfectionOnly disinfect vaginal and rectal probes. A 10-6 reduction in pathogens should be reached following the disinfection

Pagina 208 - [Figure 6.10 Exam Review]

User Manual9-20 BiopsyA biopsy is an examination method that surgically extracts tissue from the patient for examination. The probe and the biopsy kit

Pagina 209 - Using Preview

Chapter 9 Probes9-21Using the Biopsy KitWARNING: XVerify the condition of the biopsy needle before use. Do not use a bent biopsy needle.XThe biopsy

Pagina 210 - DICOM Send (Optional)

User Manual9-225. Insert the needle into the needle guide. Perform the puncture by sliding the needle through the groove in the guide until the needl

Pagina 211 - DICOM Printing (Optional)

Chapter 9 Probes9-23Cleaning and Disinfecting Biopsy KitWash and disinfect the biopsy kit to reduce pathogens to the level of 10-6. Some components o

Pagina 212 - Distance

Chapter 1 Safety 1-11  Approved Cables, Probes and Peripherals for EMC CablesCables connected to this product may aect its emissions. Refer to th

Pagina 213 - Closing SONOVIEW

User Manual9-24 Cleaning and Disinfection of plastic biopsy kit Cleaning 1. After use, remove the biopsy kit from the probe.2. Disassemble the bio

Pagina 214

Chapter 9 Probes9-25Assembling the Biopsy Kit C2-5 Biopsy Guide (Plastic)  Biopsy SpecicationsModel NameBP-KIT-045ComponentBiopsy BracketNeedle Gu

Pagina 215 - Utilities

User Manual9-263. Mount the needle guide for the desired gauge onto the adaptor.4. Install the needle into the needle guide.

Pagina 216 - Chapter 7

Chapter 9 Probes9-27 C2-5 Biopsy Guide (Metal)  Biopsy SpecicationsModel nameBP-KIT-042 ComponentBiopsy BracketNeedle Guide (16G)Needle Guide (18G

Pagina 217 - Setting System

User Manual9-283. Mount the needle guide for the desired gauge onto the adaptor.4. Install the needle into the needle guide.

Pagina 218 - Language

Chapter 9 Probes9-29 C2-8 Biopsy Guide  Biopsy SpecicationsModel nameBP-KIT-035ComponentBiopsy BracketNeedle Guide1 EA24 EAMaterialAcetal Copolyme

Pagina 219 - Autotext Set

User Manual9-303. Mount the needle guide for the desired gauge onto the adaptor.4. Install the needle into the needle guide.

Pagina 220

Chapter 9 Probes9-31 CN2-8 Biopsy Guide  Biopsy SpecicationsModel nameBP-KIT-038ComponentAdapterNeedle Guide (16G)Needle Guide (18G)Needle Guide (

Pagina 221 - Display

User Manual9-323. Mount the needle guide for the desired gauge onto the adaptor. 4. Install the needle into the needle guide.

Pagina 222 - Simultaneous Mode

Chapter 9 Probes9-33 L5-12/60 Biopsy Guide  Biopsy SpecicationsModel nameBP-KIT-039ComponentAdapterNeedle Guide (16G)Needle Guide (18G)Needle Guid

Pagina 224 - Trackball Speed

User Manual1-12Immunity test IEC 60601 Test level Compliance levelElectromagnetic environment -guidanceElectrotatic discharge (ESD)IEC 61000-4-2±6KV C

Pagina 225 - Setting Measurements

User Manual9-343. Secure the Needle Guide Clip. 4. Insert the needle into the needle guide for use.

Pagina 226

Chapter 9 Probes9-35 LE5-12 Biopsy Guide  Biopsy SpecicationsModel nameBP-KIT-040ComponentBiopsy Adapter 1 EAMaterialAcetal CopolymerAvailable Ga

Pagina 227 - Doppler

User Manual9-363. Secure the Needle Guide Clip. 4. Insert the needle into the needle guide for use.

Pagina 228 - Mean Trace

Chapter 9 Probes9-37 LN5-12 Biopsy Guide  Biopsy SpecicationsModel nameBP-KIT-040ComponentBiopsy Adapter 1 EAMaterialAcetal CopolymerAvailable Ga

Pagina 229 - [Figure 7.9 Measure - Report]

User Manual9-383. Secure the Needle Guide Clip.4. Insert the needle into the needle guide for use.

Pagina 230 - [Figure 7.10 Measure – OB]

Chapter 9 Probes9-39 LN5-12/40 Biopsy Guide  Biopsy SpecicationsModel nameBP-KIT-036ComponentAdapterNeedle Guide1 EA24 EAMaterialAcetal CopolymerA

Pagina 231 - [Figure 7.11 New Preset]

User Manual9-403. Secure the Needle Guide Clip.4. Insert the needle into the needle guide for use.

Pagina 232 - [Figure 7.12 Graph]

Chapter 9 Probes9-41 EC4-9 Biopsy guide Biopsy SpecicationsModel nameBP-KIT-024ComponentBiopsy AdapterSheath1 EA2 EAMaterialStainlessAvailable Gau

Pagina 233 - [Figure 7.13 Backup/Restore]

User Manual9-42 EVN4-9 Biopsy Guide  Biopsy SpecicationsModel nameBP-KIT-024ComponentBiopsy AdapterSheath1 EA2 EAMaterialStainlessAvailable Gauges1

Pagina 234 - Fetal Echo

Chapter 1 Safety 1-13Immunity testIEC 60601Test levelCompliance levelElectromagneticenvironment - guidanceConducted RFIEC 61000-4-63 Vrms150 kHz to

Pagina 235 - Cardiac

User Manual1-14  Recommended separation distances between portable and mobile RF communications equipment and the SONOACE R3This product is intended

Pagina 236 - Urology Measurement Setup

Chapter 1 Safety 1-15  Avoiding Electromagnetic InterferenceTypical interference on Ultrasound Imaging Systems varies depending on Electromagnetic

Pagina 237 - Chapter 7 Utilities

User Manual1-16X Is the interference intermittent or constant?X Does the interference show up only with one transducers operating at the same freque

Pagina 238 - Vascular

Chapter 1 Safety 1-17 Mechanical SafetySafety NoteCAUTION: XDo not apply excessive force to the product. XBe sure to install the console on a sta

Pagina 239 - [Figure 7.18 Setup - DICOM]

User Manual1-18 Biological SafetyVerify the alignment of the biopsy guide before use. See the “Chapter 9. Probes” section of this manual.WARNING: XU

Pagina 240 - Network Setup

Chapter 1 Safety 1-19  Applying ALARAThe system-imaging mode used depends upon the information needed. 2D-mode and M-mode imaging provide anatomica

Pagina 241

User Manual1-20  Indirect ControlsThe indirect controls are those that have an indirect effect on acoustic intensity. These controls affect imaging m

Pagina 242 - Print Server Information

Chapter 1 Safety 1-21  Additional ConsiderationsEnsure that scanning time is kept to a minimum, and ensure that only medically required scanning is

Pagina 244 - Worklist Server Settings

User Manual1-22 Mechanical Index (MI) DisplayMechanical bioeects are threshold phenomena that occur when a certain level of output is exceeded. The

Pagina 245 - Start Date

Chapter 1 Safety 1-23The measured water tank values are de-rated using a conservative, industry standard, attenuation coecient of 0.3dB/cm-MHz.Cons

Pagina 246 - DICOM Log

User Manual1-24  2D-mode Controls 2D-mode sizeNarrowing the sector angle may increase the frame rate. This action will increase the TI. Pulse voltag

Pagina 247

Chapter 1 Safety 1-25 Color Sector DepthDeeper color sector depth may automatically decrease color frame rate or select a new color focal zone or c

Pagina 248 - [Figure 7.22 Setup - Option]

User Manual1-26  Doppler, M-mode, and Color Imaging ControlsWhen a new imaging mode is selected, both the TI and the MI will change to default settin

Pagina 249 - Setting Peripheral Devices

Chapter 1 Safety 1-27WFUMB. Symposium on Safety of Ultrasound in Medicine: Conclusions and Recommendations on Thermal and Non-Thermal Mechanisms for

Pagina 250 - Printer 2

User Manual1-28l = skin line to measurement depth (cm)f = Center frequency of the transducer/system/mode combination(MHz)Since the ultrasonic path dur

Pagina 251 - [Figure 7.24 Information]

Chapter 1 Safety 1-29PD The pulse duration (microseconds) associated with the transmit pattern giving rise to the reported value of the respective

Pagina 252 - [Figure 7.26 Biopsy menu]

User Manual1-30We also refer to a September 1993 analysis done by a working group of the IEC technical committee 87 and prepared by K. Beissner, as a

Pagina 253 - [Figure 7.27 Biopsy Edit]

Chapter 1 Safety 1-31 Environmental ProtectionCAUTION: XThe console and peripherals could be sent back to manufacturers for recycling or proper di

Pagina 254 - Starting and Finishing Biopsy

SAMSUNG MEDISON DIAGNOSTIC ULTRASOUND SYSTEMVersion 2.01EnglishSONOACE R3User Manual

Pagina 256 - [Figure 7.30 Miscellaneous]

Chapter 2Specifications ...2-3Product Configuration ...2-5Monitor

Pagina 258

Chapter 2 Introduction 2-3 SpecicationsPhysical DimensionsHeight: 375mm (with handle)Width: 402mm (with probe holder)Depth: 188mm (with control pan

Pagina 259 - Maintenance

User Manual2-4ApplicationGynecology, Abdomen, OB, Renal, Urology, Vascular, Small Part, Fetal Heart, Breast, Musculoskeletal, Pediatric, Neonatal, Car

Pagina 260

Chapter 2 Introduction 2-5 Product CongurationThe SONOACE R3 consists of the monitor, the control panel, the console, the peripheral devices, and

Pagina 261 - Operating Environment

User Manual2-6 Title AreaThis section displays the Logo, Patient Name, Hospital Name, Application, Frame Rate & Depth, Probe Information, Acoust

Pagina 262 - System Maintenance

Chapter 2 Introduction 2-7Tips!Principles of Operation of the Diagnostic Ultrasound SystemMedical ultrasound images are created when the computer&ap

Pagina 263 - Accuracy Check

User Manual2-8Control PanelThe control panel can be used for controlling the system. [Figure 2.2 Control Panel]The user can manipulate the control pan

Pagina 264 - Data Maintenance

Chapter 2 Introduction 2-9  Control Panel MapThe following are descriptions and instructions for the controls on the control panel. For more inform

Pagina 266

User Manual2-10SetUse this option to select an item or value. In Spectral Doppler Mode and 3D mode, it is also used as update function. ExitExits the

Pagina 267 - Chapter 9

Chapter 2 Introduction 2-11  KeyboardsThis product comes with an alphanumeric keyboard, which can be used to enter text and run a variety of functi

Pagina 268

User Manual2-12UtilityThis button is used to appear the utility menu. App.This is used to appear Application screen to select/change probes and applic

Pagina 269 - Probe List

Chapter 2 Introduction 2-13ConsoleWhilst the inside of the console consists of devices enabling the implementation of ultrasound images, the outside

Pagina 270 - Function list

User Manual2-14  Rear PanelA monitor, printer, VCR, etc. are connected via the rear panel at the back of the system. 1236745[Figure 2.6 Rear Panel]1U

Pagina 271 - Chapter 9 Probes

Chapter 2 Introduction 2-15  Power Connection PartThe power connection part is located at the back of the system. [Figure 2.7 Power Connection Part

Pagina 272

User Manual2-16Peripheral DevicesBased on needs, various peripheral devices can be connected via the corresponding ports located on the rear panel.CAU

Pagina 273

Chapter 2 Introduction 2-17 Inkjet PrinterNOTE: Contact Samsung Medison’s customer service department about abailable printers.CAUTION: Contact Sa

Pagina 274 - TI Table

User Manual2-18ProbeProbes are devices that generate ultrasound waves and process reected wave data for the purpose of image formation.NOTE: For more

Pagina 275 - Ultrasound transmission Gel

Chapter 2 Introduction 2-19SONOACE R3 Cart (Optional)[Figure 2.10 SONOACE R3 Cart]The SONOACE R3 System can be placed on a cart during use or for tr

Pagina 276 - Probe Precautions

PROPRIETARY INFORMATION AND SOFTWARE LICENSEThe Customer shall keep condential all proprietary information furnished or disclosed to the Customer by

Pagina 277 - Electric Shocks

User Manual2-20Accessory This system provides a box including accessories.CABLE CORERCA-BNC GENDER FUSEBRACKET DV12RGB GENDERDRIVERM3*8 SCREWMANUALPOW

Pagina 278

Chapter 2 Introduction 2-21OptionsThe SONOACE R3 has the following optional functions:XImage ling-SONOVIEW XDICOMXFreehand 3DXPulse wave Dopple

Pagina 280

Chapter 3Power Supply ...3-3Powering On ...

Pagina 282

Chapter 3 Starting Diagnosis 3-3 Power SupplyBoot the system for use.CAUTION: Make sure to connect the probe and peripheral devices that will be u

Pagina 283

User Manual3-4 Probes & ApplicationsBefore scanning, select a probe and an application. CAUTION: Please refer to 'Chapter 9. Probes' fo

Pagina 284 - Cleaning

Chapter 3 Starting Diagnosis 3-5Probe and Application SelectionSet a probe and an application in the Applications screen.1. Select a probe and an a

Pagina 285 - [Figure 9.1 Disinfection]

User Manual3-6Editing BodyMarker Select some BodyMarkers to use in the system or change the order of BodyMarkers. Click Edit BodyMarker in the Applica

Pagina 286 - Biopsy Kit Components

Chapter 3 Starting Diagnosis 3-7  Back to default BodyMarkerPress the Default on ‘User dened BodyMarker preset’ to back to default BodyMarker. 

Pagina 288 - Needle Guide Alignment

User Manual3-8Calc Sequence[Figure 3.3 Calc Package Sequence Change]To change the order and content of the Calculation Package of each application, cl

Pagina 289 - Disinfection

Chapter 3 Starting Diagnosis 3-9 Patient InformationPress the Patient key on the control panel and then the Patient Information screen will be dis

Pagina 290

User Manual3-10Registering a New Patient1. After clicking the New in the Patient Information screen, enter the patient name, ID and other information

Pagina 291 - Assembling the Biopsy Kit

Chapter 3 Starting Diagnosis 3-11 GA It indicates the gestational age of a patient.You can enter it manually in the specied format, or have it au

Pagina 292

User Manual3-12 HeightEnter the patient’s height in inches or centimeters. Click the unit button to toggle the unit. If the unit is changed, the numb

Pagina 293 - C2-5 Biopsy Guide (Metal)

Chapter 3 Starting Diagnosis 3-13Searching for Patient InformationYou can search the patient information with following three methods.  Finding P

Pagina 294

User Manual3-143. After selecting ID, press Select or Ok to display information of the selected patient. To stop the search or close the current sear

Pagina 295 - C2-8 Biopsy Guide

Chapter 3 Starting Diagnosis 3-15[Figure 3.6 Modality Worklist]

Pagina 296

User Manual3-16Modifying Patient InformationTo modify information in the Patient Information screen:1. Modify the information using the trackball, Set

Pagina 297 - CN2-8 Biopsy Guide

Chapter 4Information ... 4-3Diagnosis Mode Types ...

Pagina 298

Safety Requirements Classication: XType of protection against electrical shock: Class IXDegree of protection against electrical shock (Patient c

Pagina 300

Chapter 4 Diagnosis Modes4-3 InformationDiagnosis Mode TypesThis product supports a variety of diagnosis modes including Basic Mode, Combined Mode, M

Pagina 301 - LE5-12 Biopsy Guide

User Manual4-4Basic Use The items that can be used commonly in each diagnosis mode are shown below: Gain Use the Gain dial-button on the control pane

Pagina 302

Chapter 4 Diagnosis Modes4-51. Press the Zoom key on the keyboards.2. Use the Trackball to move the Zoom box. You can locate the Zoom box in an image

Pagina 303 - LN5-12 Biopsy Guide

User Manual4-6 Harmonic Press the HAR key on the keyboards to select On or O. ‘HGen’, ‘HRes’. ‘HPen’ mark is displayed in the image information area

Pagina 304

Chapter 4 Diagnosis Modes4-7 Basic Modes2D ModeThis basic mode, also referred to as B Mode (Brightness mode), provides scan planes of organs. This i

Pagina 305 - LN5-12/40 Biopsy Guide

User Manual4-8  2D Mode Menu Following items are displayed on menu when you press the Menu dial-button in 2D mode. Select the item and adjust the val

Pagina 306

Chapter 4 Diagnosis Modes4-9 Frame RateThis is the rate by which the image displayed is updated per second. Use the Menu dial-button to select Fast,

Pagina 307 - EC4-9 Biopsy guide

User Manual4-10 2D PostBrings up the sub-menu. [Figure 4.2 2D Post]▶2D Map: Select the post map to use. Select a map between Type 1 - 5 or User 1 –

Pagina 308 - EVN4-9 Biopsy Guide

Chapter 4 Diagnosis Modes4-11Tips!Editing a post mapYou can edit the user post map with following two methods. 1. Select the each point of the map w

Comentarios a estos manuales