5-22
● Sensitivity
Determines Motion sensing sensitivity. Sensitivity grade consists of Low ➝
Medium ➝ Very High in the ascending order.
● Alarm-Out
Selects Alarm-Out scope when Motion occurs.
At this moment, this supports 5 Alarm Outs. Choose an alarm-out that you want to
synchronize with the current motion channel. Multi-choice is possible.
● Beep-Out
Determines Alarm-Out Duration. Alarm-Out continues for the determined duration.
Off/ 3sec/ 5sec/ 10sec/ 20sec/ 30sec/ 1min/ 2min
Video Loss
SHR-4080P USER’S MANUAL
5-21
Motion Detecting
● M.D State
Off : Motion Detection does not operate
On : Motion Detection starts operation.
● Area
Select the Motion Detection zone. It is composed of 45x48 sized Block. You are
forbidden to determine 4 block rows(Up/Down/Left/Right) to allow them to be
displayed in all monitors.
❿ Select All : Selects the whole area.
❿ Select One : Selects a block every time. Selection is done by a toggle system.
❿ Select Quarter : Split the whole area into 4 pieces, which enables selecting a
fourth of the whole area.
❿ Clear All : Cancels the whole area.
❿ Save & Exit : Saves and exits.
❿ Exit : Exits without saving.
● Video Loss State
Off : Video Loss does not operate.
On : Video Loss starts operation.
● Alarm-Out
Selects Alarm-Out scope when the current Video Loss occurs.
At this moment, this supports 5 Alarm Outs. Choose an alarm-out that you want to
synchronize with the current motion channel. Multi-choice is possible.
● Beep-Out
Determines Alarm-Out Duration. Alarm-Out continues for the determined duration.
Off/ 3sec/ 5sec/ 10sec/ 20sec/ 30sec/ 1min/ 2min