5-20
Alarm
● Sensor State
Off : Sensor does not operate.
① N.O(Normal Open) Sensor : Sensor remains open all the time and if closed, an
alarm will be issued. (A Contact)
➁ N.C(Normal Close) Sensor : Sensor remains closed all the time and if open, an
alarm will be issued. ( B Contact)
● Cam
Determines a camera which will synchronize with the current sensor.
The default is currently set to the sensor number. A sensor shall be synchronized
with at least a camera. Multi-synchronization is possible.
SHR-4080P USER’S MANUAL
5-19
● Quality
Recording resolution will be determined.
Choose one from Level 1(Low) to Level 8 (High). Level 8 supplies the best resolution
● Rate
Determines Frame Rate to be recorded. Frame Rate means the number of screen
recorded every second.
Set to 25ips, the system records too many screens per second and play continues
intermittently since recording is more detailed. This is appropriate for concentrated
monitoring zone setup.
25 ips/ 12.5 ips/ 8.33 ips/ 6.25 ips/ 5 ips/ 2.5 ips/ 1 ips
● PreAlarm
● PostAlarm
Records the situation until Alarm is issued.
Off : No recording
3sec/ 5sec/ 10sec/ 20sec/ 30sec : The recording time options before Alarm issue
Records the situation since Alarm is issued.
Off : No recording
3sec/ 5sec/ 10sec/ 20sec/ 30sec/1min/3min/5min/10min/20min :
To this, the recording time after Alarm issue is set.
Note
Note
[Monitor Out]
You are not allowed to set up “25ips” of Rate and Video sized “Full D1” simultane-
ously. The system does not support both at once.
Pre Alarm Section
Event occurred point of time
Post Alarm Section
Event occurred point of time
● Alarm-Out
Arranges Alarm-Out when Alarm Sensor sounds.
At this moment, this supports 5 Alarm Outs. Choose an alarm-out that you want to
synchronize with the current sensor. Multi-choice is possible.
● Beep-Out
Determines Alarm-Out Duration. Alarm-Out continues for the determined duration.
Off/ 3sec/ 5sec/ 10sec/ 20sec/ 30sec/ 1min/ 2min