Samsung PT60A Manual de usuario

Busca en linea o descarga Manual de usuario para De medición, control y control Samsung PT60A. Samsung PT60A User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 228
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente

Indice de contenidos

Pagina 2

Precautions For UseBe sure to read this manual thoroughly to familiarize yourself with the operation of the product and the relevant safety informat

Pagina 3

4-6Operation Manual Basic Mode2D ModeThis basic mode, also referred to as B Mode (Brightness mode), provides scan planes of organs. This is used to d

Pagina 4

4-7Chapter 4 Diagnosis Modes[Figure 4.2 2D Mode - More]  Entering 2D ModeNOTE: Because 2D Mode is applied by default for all diagnosis modes, it can

Pagina 5

4-8Operation Manual Freq.(Frequency)This enables you to congure the probe’s frequency. Tap Freq. on the touch screen. You may select from Res, Pen,

Pagina 6

4-9Chapter 4 Diagnosis Modes SDMRNOTE: SDMR is an optional feature of this product.Tap SDMR on the touch screen to select 1, 2, or O. You can obta

Pagina 7

4-10Operation ManualBiopsy GuideSelect Biopsy on the touch screen.NOTE: XMake sure to adjust the biopsy guideline before using the biopsy feature.XT

Pagina 8 - Safety Requirements

4-11Chapter 4 Diagnosis Modes  Starting and Finishing a BiopsyNOTE: Make sure to adjust the biopsy guideline before using the biopsy feature.1. Pre

Pagina 9 - Declarations

4-12Operation ManualM ModeThe M Mode is used to specify an observation area in a 2D image with the M Line, and display changes over time.This mode is

Pagina 10 - Precautions For Use

4-13Chapter 4 Diagnosis Modes  M Mode Menu Sweep SpeedUse the Sweep Speed ‘-/+’ buttons to select either 20mm/s, 30mm/s, 40mm/s, or 60mm/s. Time

Pagina 11 - Revision History

4-14Operation ManualColor Doppler ModeThis mode displays the colored blood ow pattern of the ROI (Region of Interest) within the 2D image.It is appro

Pagina 12

4-15Chapter 4 Diagnosis Modes Color BarIn Color Doppler mode, the color bar indicates the direction and speed of blood ow. Based on the baseline a

Pagina 13 - Table of Contents

Revision HistoryThe revision history of this operation manual is as follows: VERSION DATE NOTEv1.00.00-00 2013-05-08Initial Releasev1.00.00-01 2013-

Pagina 14 - Chapter 4 Diagnosis Modes

4-16Operation Manual Baseline Press the ‘ / ‘ buttons of Baseline to adjust the baseline. In Color Doppler mode, the color bar indicates the directi

Pagina 15 - Chapter 6 Image Management

4-17Chapter 4 Diagnosis ModesPower Doppler ModeThis mode provides a color representation of blood ow intensity within the ROI in a 2D image. It is s

Pagina 16 - Chapter 8 Maintenance

4-18Operation Manual  PD Mode MenuNOTE: The description of touch screen menu items is the same as for ‘Color Doppler Mode’.[Figure 4.9 Power Doppler

Pagina 17 - Chapter 9 Probes

4-19Chapter 4 Diagnosis ModesPW Spectral Doppler Mode PW stands for Pulse Wave. This mode displays the blood ow speed at a specic blood vessel loca

Pagina 18

4-20Operation Manual  Entering & Exiting PW Spectral Doppler ModeTap the PW button on the touch screen. Tap the Update button on the touch screen

Pagina 19 - Chapter 1

4-21Chapter 4 Diagnosis Modes Wall FilterRemoves Clutter Signal. Tap the Wall Filter ‘+/-’ buttons to select O, L, M, or H. SoundAdjusts the Dop

Pagina 20

4-22Operation Manual Combined ModeIn Combined Mode, three dierent modes are combined, including the default 2D Mode. Note that, in 2D/C Live Mode, o

Pagina 21 - Indication for Use

Measurement Accuracy ...5-3Causes of Measurement Errors ...5-3Optimization of

Pagina 23 - Chapter 1 Safety

5-3Chapter 5 Measurements and Calculations Measurement AccuracyMeasurement values can vary depending on the nature of the ultrasound wave, the body’

Pagina 25

5-4Operation Manual  Ultrasound VelocityXThe average velocity of ultrasound used for measurement is usually 1,540m/s.XThe velocity of ultrasound ma

Pagina 26 - Electrical Safety

5-5Chapter 5 Measurements and CalculationsOptimization of Measurement Accuracy  2D ModeXResolution is in proportion to the frequency of the probe.

Pagina 27

5-6Operation Manual  Color/Power Doppler ModeXA protocol is not specied for images in Color Doppler Mode or Power Doppler Mode. Therefore, the same

Pagina 28 - ECG-Related Information

5-7Chapter 5 Measurements and CalculationsMeasurement Accuracy TableThe following tables show the accuracy of the measurements available using the pr

Pagina 29

5-8Operation Manual Basic MeasurementsTap the Meas. button on the touch screen’s soft menu. The Meas. button is only enabled in Freeze state.NOTE: Ta

Pagina 30 - Peripheral Devices

5-9Chapter 5 Measurements and Calculations  Basic Measurement OperationsThe following is the information on common button operations for basic measu

Pagina 31

5-10Operation Manual[Figure 5.1 Caliper]Distance measurement  DistanceThis is a basic measurement that is available in all diagnosis modes. You can s

Pagina 32

5-11Chapter 5 Measurements and CalculationsTips!Repositioning PointYou may drag and drop the start point or the end point to change their position af

Pagina 33

5-12Operation Manual  Distance (M)This is a basic measurement that is only available in M Mode. You can specify two points in an M image and measure

Pagina 34

5-13Chapter 5 Measurements and Calculations  VelocityThis is a basic measurement that is only available in Spectral Doppler Mode. You can specify on

Pagina 35

13Table of ContentsTable of ContentsChapter 1 SafetyIndication for Use ...

Pagina 36 - Mechanical Safety

5-14Operation ManualXPS/ED: PS ED RatioXED/PS: ED PS RatioThe formulae used for Manual Trace measurement are as follows:XDuration of flowVTImeanV =

Pagina 37 - Moving the Equipment

5-15Chapter 5 Measurements and CalculationsThe equations used for D Limited Trace measurement are as follows:XDuration of flowVTImeanV =XPSEDPSRI−=

Pagina 38 - Biological Safety

5-16Operation Manual  HRThis is a basic measurement that is only available in Spectral Doppler Mode. You can specify two bars on a Spectral Doppler i

Pagina 39 -  Direct Controls

5-17Chapter 5 Measurements and CalculationsThe following equation is used for Ellipse measurement: , (a: Half Long axis, b: Half Short axis)Area =, (

Pagina 40 -  Indirect Controls

5-18Operation ManualVolume measurementNOTE: Since Dual Mode simultaneously displays two images on the screen, you don’t have to return to the diagnosi

Pagina 41 -  Output Display Features

5-19Chapter 5 Measurements and Calculations Calculations by ApplicationTap the Meas. button on the touch screen’s soft menu, and tap the Calc. butto

Pagina 42 - Thermal Index (TI) Display

5-20Operation Manual Delete Trace LineDelete a trace line by reversing the dragging direction. You can only use this function when you are Manually

Pagina 43

5-21Chapter 5 Measurements and CalculationsCommon Measurement MethodsThis section provides information on the common measurement methods used for app

Pagina 44 -  Color and Power Controls

5-22Operation Manual1. Select Auto Trace from the measurement menu. The system will automatically trace the spectrum.2. Two bars will appear at the

Pagina 45 - Sample Volume Depth

5-23Chapter 5 Measurements and CalculationsOB CalculationsNOTE: XFetal HR can only be measured in Doppler Mode.XFor information on basic measuremen

Pagina 47

5-24Operation ManualMeasurement Menu Item Mode Method UnitFetal BiometryGS 2D Distance measurement cmCRL 2D Distance measurement cmBPD 2D Distance m

Pagina 48 - -(0,069 lf)

5-25Chapter 5 Measurements and Calculations  Calculating Estimated Fetal Weight (EFW)When measurements for the following items are complete, the sys

Pagina 49

5-26Operation ManualGynecology Calculations NOTE: XFor information on basic measurement methods, refer to ‘Basic Measurements’ and ‘Common Measuremen

Pagina 50

5-27Chapter 5 Measurements and CalculationsMeasurement Menu Item Mode Method UnitFollicle#1 All Volume measurement ml#2 All Volume measurement Ml#3 A

Pagina 51 - Systematic Uncertainties

5-28Operation ManualVascular CalculationsThe measurement method for each item is the same as for basic measurement. NOTE: XFor information on basic m

Pagina 52 -  Training

5-29Chapter 5 Measurements and Calculations[Figure 5.2 Auto IMT]

Pagina 53 - Protecting the Environment

5-30Operation ManualEchocardiographic Measurement (Cardiac Calculations)The measurement method for each item is the same as for basic measurement. Mea

Pagina 54 - Battery Pack

5-31Chapter 5 Measurements and Calculations ReportThe measurement results are summarized by application, and shown on the screen in a report format.V

Pagina 55

5-32Operation Manual  Measurement Display MethodThe product allows you to measure one measurement item several times. However, only the rst three me

Pagina 56

5-33Chapter 5 Measurements and CalculationsAdding CommentsTap Comment on the touch screen’s soft menu to switch to the screen for entering opinions o

Pagina 57 - Introduction

15Table of ContentsChapter 5 Measurements and CalculationsMeasurement Accuracy ...

Pagina 58

5-34Operation ManualPrinting ReportsTap the Print button on the soft menu. The measurement report for the selected application will be printed on the

Pagina 59 - Product Specications

Cine / Loop ...6-3Annotating Images ...6-5Annotation .

Pagina 61 - Product Conguration

6-3Chapter 6 Image Management Cine / LoopImages are automatically saved in the memory during scanning. The saved images are useful for patient diagn

Pagina 62 -  Touch Screen

6-4Operation Manual  How to Review ImagesMove the cursor to the bar to review an image. You can search through saved images in chronological order by

Pagina 63 - Chapter 2 Introduction

6-5Chapter 6 Image Management Annotating ImagesAnnotationEnter or display text, Arrows, or BodyMarkers on an image. This function is useful for die

Pagina 64 -  Touch Panel

6-6Operation Manual  Entering Text 1. Press the Annotation button on the soft menu, and then press the Text button to switch to Text Entry mode.2.

Pagina 65 - Console

6-7Chapter 6 Image Management SpaceEnter a space in the Text Entry window. BackSpaceDelete the previous character. ExitExit the Text Library me

Pagina 66 -  Console - Bottom

6-8Operation Manual  Entering Arrow 1. Press Annotation button on the soft menu, and then press the Arrow button to switch to entry mode.2. To adju

Pagina 67

6-9Chapter 6 Image ManagementBodyMarkerEnter a BodyMarker on an image. This function is useful for dierentiating or marking a diagnosis area.  Star

Pagina 68 - Foot Switch

16Operation ManualChapter 7 UtilitiesSystem Settings ...

Pagina 69 - Video Out

6-10Operation Manual  Changing the Probe Cursor AnglePress the Rotate button on the soft menu.  Repositioning BodyMarker1. Press the Move Marker bu

Pagina 70

6-11Chapter 6 Image Management Saving, Playing and Transferring ImagesSaving ImagesWARNING: You must enter the patient ID because all images are sav

Pagina 71 - Battery Pack

6-12Operation ManualTransferring ImagesUGEO PT60A allows you to transfer images to a PACS system that supports DICOM. You can transfer all saved image

Pagina 72 -  Battery Icons

6-13Chapter 6 Image Management SonoView ModeSonoView is UGEO PT60A's integrated image management program. It oers image saving/ling, preview,

Pagina 73 -  Connecting Probes

6-14Operation Manual  Launching SonoView ModePress the SonoView button on the soft menu. The screen will switch to the SonoView screen.If there are

Pagina 74 - UGEO PT60A CART (Optional)

6-15Chapter 6 Image ManagementExam ModePress the SonoView button on the soft menu. In the Exam Mode, you can review the current or saved exam.[Figure

Pagina 75 - Accessories

6-16Operation Manual  Selecting ImageSelect images in the Thumbnail List. The selected image is highlighted in yellow in the list. Specify the positi

Pagina 76

6-17Chapter 6 Image Management  Transferring Images via DICOMTransfer the selected image and measurement data via DICOM. The icon is only enabled wh

Pagina 77 - Optional Functions

6-18Operation Manual  Deleting ImagesPress the Delete button to delete the selected image.  Exiting SonoViewPress the Exit button on the soft menu.

Pagina 78

System Settings ...7-3General System Settings ...7-

Pagina 79 - Starting Diagnosis

17Table of ContentsChapter 9 ProbesProbes ...

Pagina 81 - System Power

7-3Chapter 7 Utilities System SettingsGeneral system settings that do not aect the image are described. These settings may be changed as needed o

Pagina 82 - Shutting Down the System

7-4Operation ManualGeneral System SettingsOn the Setup screen, tap the System button on the touch screen. You can specify general settings such as tit

Pagina 83 - Probes and Applications

7-5Chapter 7 Utilities  Date and TimeCongure the system's date and time settings.Today's date is displayed. To change the date, tap .NO

Pagina 84 - Patient Information

7-6Operation ManualScreen Display Settings (Imaging)On the Setup screen, tap the Imaging button on the touch screen to congure settings for image dis

Pagina 85

7-7Chapter 7 Utilities  Application Settings Thermal Index TypeSpecify the TI to display on the screen as TIs (Soft tissue Thermal Index), TIb (

Pagina 86

7-8Operation Manual  Arrow Arrow SizeSelect the arrow size (Small or Large). Arrow TypeSelect the arrow shape (Arrow or Hand).Measurement Setting

Pagina 87

7-9Chapter 7 Utilities  Heart Rate CycleSet the number of beats for the heart rate (HR) cycle. This is the setting for the HR Cycle that will be

Pagina 88 -  Vascular

7-10Operation Manual Gestational AgeSpecify the Fetal Age Author for each Label. Fetal GrowthSpecify the Fetal Growth Author for each Label.  EFW

Pagina 89 -  Pediatric

7-11Chapter 7 Utilities Peripheral Device SettingsOn the Setup screen, select the Periph. button to congure the peripheral devices connected to the

Pagina 91 -  Emergency

7-12Operation Manual  Store StoreStores the image. Store/printStores and prints the image.  Brightness Screen BrightnessSelect the screen brig

Pagina 92 - Searching Patient Information

7-13Chapter 7 Utilities Network SettingsOn the Setup screen, tap the Net button to congure the general settings for wired and/or wireless networks.

Pagina 93 -  Worklist Search

7-14Operation ManualDICOM Settings Select the DICOM button on the Setup screen.NOTE: For more information, please refer to the server’s user manual, o

Pagina 94

7-15Chapter 7 Utilities  AE TitleEnter a name for the DICOM AE (Application Entity). This is used to identify devices that use DICOM on the networ

Pagina 95 - Diagnosis Modes

7-16Operation Manual Port No.Enter the Port Number for the server being used. Please contact your organization’s network administrator to nd out th

Pagina 96

7-17Chapter 7 Utilities Storage Server InformationSelect the ‘STORAGE’ item from the combo boxes at the top right corner. Set up the image storage s

Pagina 97 - Information

7-18Operation ManualStorage SR Server InformationSelect the ‘STORAGE SR’ item from the combo boxes at the top right corner. Set up the DICOM server to

Pagina 98 - Basic Operating Instructions

7-19Chapter 7 Utilities ServiceOn the Setup screen, tap the Service button. Users should not attempt to perform anything on their own. They must con

Pagina 99

7-20Operation ManualInfoOn the Setup screen, tap the Info button; the software version information for the product will be displayed. You may view the

Pagina 100 - Basic Mode

Operational Environment ...8-3Product Maintenance ...8-4Cleaning and disinfecting .

Pagina 101 -  2D Mode Menu

Indication for Use ...1-3Contraindications ...

Pagina 103 - ROI Control

8-3Chapter 8 Maintenance Operational EnvironmentWhen installing the product, please pay attention to the following information.CAUTION: If the pro

Pagina 104 - Biopsy Guide

8-4Operation Manual Product MaintenanceCleaning and disinfectingUsing an inappropriate cleaning or sterilizing agent may damage the product. Take the

Pagina 105 - Needle Mate

8-5Chapter 8 Maintenance  DisinfectingCAUTION: When disinfecting the product's exterior, be sure to use disinfectants recommended by Samsung

Pagina 106 -  M Mode Screen

8-6Operation Manual Battery Pack ManagementBattery packs are consumables, and their capacity to hold charge gradually decreases as they are used. Whe

Pagina 107 -  M Mode Menu

8-7Chapter 8 Maintenance  Connecting a Battery PackConnect the battery pack as follows:1. Turn o the system and disconnect the power cord from t

Pagina 108 - Color Doppler Mode

8-8Operation Manual [Figure 8.2 Docking to Cart]The battery pack must be charged and discharged within the following temperature ranges:State Ambient

Pagina 109 -  C Mode Menu

8-9Chapter 8 Maintenance Storing the Battery PackIf you are not planning on using your UGEO PT60A, be sure to remove the battery pack from the produ

Pagina 110 - Baseline

8-10Operation Manual Information MaintenanceCAUTION: Back up the data on the system on a regular basis, since an external shock or an internal error

Pagina 111 - Power Doppler Mode

Probes ...9-3Using Ultrasound Gel ...

Pagina 115 - Wall Filter

9-3Chapter 9 Probes ProbesThe probe is a device that sends and receives ultrasound for acquiring image data.It is also called a Transducer or Scanh

Pagina 116 - Combined Mode

9-4Operation ManualProbes ApplicationLN5-12Small PartsVascularMSKAnesthesiaLS6-15MSKAnesthesiaPN2-4AbdomenCardiacTCDEmergencyNOTE: For more informatio

Pagina 117 - Calculations

9-5Chapter 9 Probes  Function ListThe functions you can use on UGEO PT60A for each probe and application are as follows: Probes Application Q Scan

Pagina 118

9-6Operation Manual  Thermal Index (TI) TablesThe Thermal Index (TI) is displayed in the Title area of the screen, and represents the probability of

Pagina 119 - Measurement Accuracy

9-7Chapter 9 Probes Using Ultrasound GelUsing an inappropriate ultrasound gel may damage the probe. For proper transmission of the acoustic beam, on

Pagina 120 -  Human Error

9-8Operation ManualUsing SheathsSheaths are recommended for clinical applications of invasive nature, including intraoperative, transrectal, transvagi

Pagina 121 -  Doppler Mode

9-9Chapter 9 Probes Probe Safety PrecautionsCAUTION: XDo not apply mechanical shock to the probe.XDo not place the probe cable on the floor where

Pagina 122 -  Cursor Position

9-10Operation Manual  Electric ShocksThe probe uses electrical energy. If it touches conductive materials, there are risks of electric shocks to the

Pagina 123 - Measurement Accuracy Table

9-11Chapter 9 Probes Cleaning and Disinfecting the ProbeWARNING: XAlways use protective eyewear and gloves when cleaning and disinfecting probes.X

Pagina 124 - Basic Measurements

1-3Chapter 1 Safety Indication for UseThe UGEO PT60A Diagnostic Ultrasound System and transducers are intended for diagnostic ultrasound imaging an

Pagina 125 - Exiting Basic Measurement

9-12Operation ManualNamesDisinfectantsCidex OPA 2,3,6)Cidex Plus 2)Metricide 2)Omnicide (28)Omnicide 14NSOmnicide - FG2NucleanWavicide-01 3)Sekusept

Pagina 126 - Distance measurement

9-13Chapter 9 Probes NamesDisinfectants CleanerVirkonSporoxSporox IIGigaseptGigasept AF 3)Gigasept FFHibitanePeraSafeEnzolAlkazymeCidezymeKlenzymeIs

Pagina 127 -  Angle

9-14Operation ManualNamesCleaner GelEthanol 75%MetrizymeMcKessonNatural ImageAquasonics 100 3)GE Ultrasound Contact GelClear ImageKendallScanWavelengt

Pagina 128 -  Slope

9-15Chapter 9 Probes Tips!SymbolsThe significance of each symbol is as follows: (1) Compatible but no EPA Registration (2) FDA 510 (k) Cleared (3)

Pagina 129 -  Manual Trace

9-16Operation ManualThe following is information about the manufacturers (or Distributors) of detergents, disinfectants, and ultrasound gels.Product M

Pagina 130 - Duration of flow

9-17Chapter 9 Probes  CleaningCleaning is an important procedure that is carried out before disinfecting the probe. The probe must be cleaned aft

Pagina 131

9-18Operation Manual  DisinfectionDisinfect the probe using a disinfectant solution recommended by Samsung Medison to reduce pathogens to the level o

Pagina 132 -  Ellipse

9-19Chapter 9 Probes BiopsyA biopsy is an examination method that surgically extracts tissue from the patient for examination. The probe and the bi

Pagina 133 -  Trace

9-20Operation ManualUsing the Biopsy KitWARNING: XVerify the condition of the biopsy needle before use. Do not use a bent or warped biopsy needle.XT

Pagina 134 - Volume measurement

9-21Chapter 9 Probes  Biopsy ProcedureThe system generates a needle guideline using the ultrasound image displayed in real-time to anticipate the

Pagina 135 - Calculations by Application

1-4Operation Manual Safety InformationPlease read the following safety information before using this product. It is relevant to the ultrasound system

Pagina 136 - Operation Manual

9-22Operation Manual  Needle Guide AlignmentWARNING: XDo not use the same needle used to verify alignment for an actual biopsy application. Always u

Pagina 137 - Common Measurement Methods

9-23Chapter 9 Probes Cleaning and Disinfecting the Biopsy KitWARNING: Always use protective eyewear and gloves when cleaning and disinfecting biopsy

Pagina 138 -  Heart Rate Measurement

9-24Operation Manual  Cleaning and Disinfecting of Plastic Biopsy Kit Cleaning 1. After use, remove the biopsy kit from the probe.2. Disassemble

Pagina 139 - OB Calculations

9-25Chapter 9 Probes Assembling the Biopsy Kit  C2-5 Biopsy Guide Biopsy SpecicationsModel nameBP-KIT-045ComponentsBiopsy AdapterNeedle Guide (1

Pagina 140 -  AFI(Amniotic Fluid Index)

9-26Operation Manual3. Mount the needle guide for the desired gauge onto the adapter.4. Install the needle into the needle guide for use.

Pagina 141

9-27Chapter 9 Probes  C2-8 Biopsy Guide  Biopsy SpecicationsModel nameBP-KIT-035ComponentsBiopsy AdapterNeedle Guide (16G)Needle Guide (18G)Nee

Pagina 142 - Gynecology Calculations

9-28Operation Manual3. Mount the needle guide for the desired gauge onto the adapter.4. Install the needle into the needle guide for use.

Pagina 143

9-29Chapter 9 Probes  LN5-12 Biopsy Guide  Biopsy SpecicationsModel nameBP-KIT-040ComponentsBiopsy Adapter Needle Guide (16G) Needle Guide (18G

Pagina 144 - Vascular Calculations

9-30Operation Manual3. Mount the needle guide for the desired gauge onto the adapter.4. Install the needle into the needle guide for use.

Pagina 145 - [Figure 5.2 Auto IMT]

1-5Chapter 1 SafetySymbols Description Symbols DescriptionWARNING: Follow these instructions to prevent a serious accident or damage to property.Prot

Pagina 146

1-6Operation ManualLABELWarning and caution labels that contain information and instructions concerning the protection of the product can be found on

Pagina 147 - Viewing Reports

1-7Chapter 1 Safety[Label 3. Probe ID label]

Pagina 148 -  Measurement Display Method

1-8Operation Manual Electrical SafetyThis equipment has been veried as a Class I device.Prevention of Electric ShocksWARNING: XElectric shocks may

Pagina 149 - Store SR

1-9Chapter 1 SafetyCAUTION: XThe system has been designed for 100-240VAC; you should select the input voltage of any connected printer and VCR. Prio

Pagina 150 - Closing Reports

1-10Operation ManualECG-Related InformationWARNING: XThis device is not intended to provide a primary ECG monitoring function, and therefore does not

Pagina 151 - Image Management

1-11Chapter 1 SafetyEMIAlthough this system has been manufactured in compliance with existing EMI (Electro-Magnetic Interference) requirements, use o

Pagina 153 - Cine / Loop

1-12Operation Manual  Approved Cables, Probes and Accessories for EMC Approved Cable for Electromagnetic ComplianceCables connected to this product

Pagina 154 -  Cine Speed

1-13Chapter 1 SafetyImmunity test IEC 60601 Test level Compliance levelElectromagnetic environment - guidanceElectrostatic discharge (ESD)IEC 61000-4

Pagina 155 - Annotating Images

1-14Operation ManualImmunity testIEC 60601test levelCompliance levelElectromagnetic environment - guidanceConducted RFIEC 61000-4-63 Vrms150 kHzto 80

Pagina 156 -  Text Library Menu

1-15Chapter 1 Safety  Recommended separation distances between portable and mobile RF communications equipment and the UGEO PT60AThis product is int

Pagina 157 -  Arrow Mode

1-16Operation ManualCAUTION: If the system is connected to customer-supplied equipment, such as a local area network (LAN) or a remote printer, Samsun

Pagina 158 -  Deleting Arrows

1-17Chapter 1 SafetyA medical device can either generate or receive electromagnetic interference. The EMC standards describe tests for both emitted a

Pagina 159 - BodyMarker

1-18Operation Manual Mechanical SafetyPrecautions for UseCAUTION: XDo not apply excessive force to the product. XNever attempt to modify the produc

Pagina 160 - Exiting Annotation

1-19Chapter 1 SafetyMoving the EquipmentFirmly grip the handle on the front of the product and move the product slowly. Alternatively, you can use th

Pagina 161 - Saving Images

1-20Operation Manual Biological SafetyFor safety information on the probe and biopsy, refer to ‘Chapter 9. Probes’.WARNING: XUltrasound waves may ha

Pagina 162 - Transferring Images

1-21Chapter 1 Safety  Applying ALARAThe system-imaging mode used depends upon the information needed. 2D-mode and M-mode imaging provide anatomical

Pagina 164 -  Launching SonoView Mode

1-22Operation Manual  Indirect ControlsThe indirect controls are those that have an indirect eect on the acoustic intensity. These controls aect th

Pagina 165 - Exam Mode

1-23Chapter 1 Safety  Additional ConsiderationsEnsure that scanning time is kept to a minimum, and ensure that only medically required scanning is p

Pagina 166 -  Clip Play/Pause/Stop

1-24Operation Manual Mechanical Index (MI) DisplayMechanical bioeects are threshold phenomena that occur when a certain level of output is exceeded

Pagina 167 -  Print

1-25Chapter 1 Safetyunderwater are de-rated using a conservative, industry standard, attenuation coecient of 0.3dB/cm-MHz.Conservative values for ti

Pagina 168 -  Exiting SonoView

1-26Operation Manual  Control Eect- Controls Aecting the IndicesAs various system controls are adjusted, the TI and MI values may change. This will

Pagina 169 - Utilities

1-27Chapter 1 Safety Color Sector DepthDeeper color sector depth may automatically decrease the color frame rate, or select a new color focal zone

Pagina 170

1-28Operation Manual  Other 2D, Color, M, Doppler Modes (2D, Color, M-Mode, PW)When a new imaging mode is selected, both the TI and the MI will rev

Pagina 171 - System Settings

1-29Chapter 1 SafetyXBioeects and Safety of Diagnostic Ultrasound (AIUM, 1993)XGuidelines for the safe use of diagnostic ultrasound equipment. (BM

Pagina 172 - General System Settings

1-30Operation ManualThe Acoustic output for this system has been measured and calculated in accordance with the Standard for Real-Time Display of Ther

Pagina 173 -  Screen Saver

1-31Chapter 1 Safety  Terms and Symbols Related to Acoustic Output and MeasurementThe terms and symbols used in the acoustic output tables are dene

Pagina 174 -  Common Settings

Diagnostic Ultrasound SystemMI68-02768AOperation ManualVersion 1.00.00English

Pagina 175 - Annotation Settings

1-32Operation ManualPr at max. IpiThe peak rarefactional acoustic pressure at the location where PULSE-INTENSITY INTEGRAL is maximal (unit: MPa)prr PU

Pagina 176 - Measurement Settings

1-33Chapter 1 Safety  Acoustic Measurement Precision and UncertaintyThe Acoustic Measurement Precision and Acoustic Measurement Uncertainty are desc

Pagina 177 -  Author Settings

1-34Operation ManualXLinearity of the balance system.XExtrapolation to the moment of switching the ultrasonic transducer (compensation for ringing a

Pagina 178 -  EFW Settings

1-35Chapter 1 Safety Protecting the EnvironmentCAUTION: XFor disposal of the system or accessories that have come to the end of their lifespan, con

Pagina 179 - Peripheral Device Settings

1-36Operation Manual Battery PackFamiliarize yourself with the instructions below before using the battery pack:WARNING: XComply with all instructio

Pagina 180 -  Brightness

1-37Chapter 1 Safety Correct Disposal of Batteries in This ProductApplicable in countries with separate collection systemsThis marking on the battery

Pagina 182 - DICOM Settings

Product Specications...2-3Product Conguration ...2-5Monitor ...

Pagina 184 - Worklist Service Server

2-3Chapter 2 Introduction Product SpecicationsPhysical DimensionsSYSTEM:Height: 252.6 mm, Width: 291 mm, Depth: 52.2 mmWeight: 3.6kg (Including bat

Pagina 186 - Storage SR Server Information

2-4Operation ManualSignal processing(Pre-processing)Mode-independent gain controlAcoustic power control (adjustable)Dynamic apertureDynamic apodizatio

Pagina 187

2-5Chapter 2 Introduction Product CongurationThis product consists of a monitor, a console, peripheral devices, and probes.215431 Touch Panel2 Touc

Pagina 188

2-6Operation ManualMonitorThe monitor consists of a touch screen and a touch panel.  Touch ScreenFor this product, the touch screen displays ultrasou

Pagina 189 - Maintenance

2-7Chapter 2 Introduction4 Soft Menu AreaDisplays Soft Menu touch buttons that can be used in the current mode.Tips!Current System StatusIndicates th

Pagina 190

2-8Operation Manual  Touch PanelA control menu located in the glass part at the bottom of the monitor, with which you can set up patient information

Pagina 191 - Operational Environment

2-9Chapter 2 IntroductionConsole The console consists chiey of ultrasound imaging components on the inside, and various connectors and a handle on t

Pagina 192 - Product Maintenance

2-10Operation Manual  Console – Left SidePower Port  Console – Right SideProbe PortSecurity Lock Port (Kensington Lock)USB port  Console - Top11SD

Pagina 193 - Accuracy Checks

2-11Chapter 2 IntroductionPeripheral DevicesPeripheral devices can be connected to their corresponding ports on the left/right or rear sides of the c

Pagina 194 - Battery Pack Management

2-12Operation ManualThe following products are recommended: USB Video PrinterXColor: Mitsubishi CP30DW, SONY UP-D25MDXBlack and White: Mitsubishi

Pagina 195 - Recharging the Battery Pack

2-13Chapter 2 IntroductionVideo OutThe optional Video Out device connects to the system to provide digital and analog video outputs.The Video Out dev

Pagina 196

PROPRIETRAY INFORMATION AND SOFTWARE LICENSEThe Customer shall keep confidential all proprietary information furnished or disclosed to the Customer by

Pagina 197 - Disposing of the Battery Pack

2-14Operation ManualConnect the Video Out device to the console in the following order:1. Connect the AC adapter to the AC adapter connection port on

Pagina 198 - Information Maintenance

2-15Chapter 2 IntroductionBattery PackThe battery pack of this product contains lithium ion batteries. Use this battery pack if you are not using an

Pagina 199 - Chapter 9

2-16Operation Manual  Battery IconsIcons that indicate the battery status are displayed in the User Information Area on the screen. If you are using

Pagina 200

2-17Chapter 2 IntroductionProbesProbes are devices that generate ultrasound waves and process reected wave data for the purpose of image formation.N

Pagina 201 -  Probe List

2-18Operation ManualUGEO PT60A CART (Optional)NOTE: UGEO PT60A CART is an optional feature of this product.The UGEO PT60A CART is a convenient platfor

Pagina 202

2-19Chapter 2 IntroductionAccessoriesA box containing various accessories is supplied with this product.SONO GELSYSTEM POWER CABLESYSTEM ADAPTERCRADL

Pagina 203 - Function List

2-20Operation ManualCRADLEThe supplied cradle is manufactured only for UGEO PT60A. Please place the product on the cradle to perform an exam safely. [

Pagina 204 -  Thermal Index (TI) Tables

2-21Chapter 2 IntroductionOptional FunctionsThis product has the following optional features. XDICOMXSDMRXAuto IMTFor further information about op

Pagina 206 - Using Sheaths

System Power ...3-3AC Adapter Connection ... 3-

Pagina 207 - Probe Safety Precautions

Safety Requirements Classifications: XType of protection against electrical shock: Class IXDegree of protection against electrical shock (Patien

Pagina 209

3-3Chapter 3 Starting Diagnosis System PowerBoot up the system for use.CAUTION: Before turning the power on, connect the probes and peripheral devic

Pagina 210

3-4Operation ManualTurning the Power On While the power is turned o, press the On/O button. Booting will start, and the product logo will be display

Pagina 211

3-5Chapter 3 Starting Diagnosis Probes and ApplicationsBefore starting a scan, select a probe and an application.CAUTION: Refer to ‘Chapter 9. Probe

Pagina 212

3-6Operation Manual Patient Information Tap the Patient button on the touch panel, and the Patient screen will be displayed.In this screen, you can e

Pagina 213

3-7Chapter 3 Starting Diagnosis Patient IDEnter patient ID. Last NameEnter the patient’s last name. First Name Enter the patient’s rst name.

Pagina 214

3-8Operation Manual Auto IDCreate temporary patient information using a temporary ID. Start ExamStart an exam. WorklistPerform a search by conne

Pagina 215 -  Cleaning

3-9Chapter 3 Starting DiagnosisPatient Information for Each ApplicationIn Study Information, enter additional patient information or change the exist

Pagina 216 -  Disinfection

3-10Operation Manual  GynecologyFrom Application, select Gynecology to enter additional information relevant to gynecology. The information entered i

Pagina 217 - Biopsy Kit Components

3-11Chapter 3 Starting Diagnosis  AbdomenSelect Abdomen in Application. HeightEnter the patient’s height in centimeters (cm), feet (ft), inch (in)

Pagina 218 - Using the Biopsy Kit

X Medical Electrical Equipment, Part 2-37: Particular Requirements for Safety - Ultrasonic Medical Diagnostic and Monitoring Equipment [IEC 60601-2-3

Pagina 219 -  Biopsy Procedure

3-12Operation Manual  Small PartsSelect Small Parts in Application. HeightEnter the patient’s height in centimeters (cm), feet (ft), inch (in). W

Pagina 220 -  Needle Guide Alignment

3-13Chapter 3 Starting Diagnosis  AnesthesiaSelect Anesthesia in Application. HeightEnter the patient’s height in centimeters (cm), feet (ft), inc

Pagina 221 - Disinfection

3-14Operation ManualSearching Patient Information  SearchSearch through the information stored in the system.[Figure 3.3 Search]1. Select the Search

Pagina 222 - Sterilization

3-15Chapter 3 Starting Diagnosis  Worklist SearchPerform a search by connecting to the DICOM Modality Worklist server in the hospital network.NOTE:

Pagina 224

Information ...4-3Types of Diagnosis Modes ... 4-

Pagina 226

4-3Chapter 4 Diagnosis Modes InformationTypes of Diagnosis ModesThis product supports Basic Mode and Combined Mode. Basic Mode: Consists of dieren

Pagina 227 -  LN5-12 Biopsy Guide

4-4Operation ManualBasic Operating InstructionsThe items that are commonly used in each diagnosis mode are shown below:  Using the Touch Screen Menus

Pagina 228

4-5Chapter 4 Diagnosis Modes Q ScanNOTE: The Quick Scan function is only available with specific probes and applications.Use the Q Scan button on t

Comentarios a estos manuales