Connecting the assembly cable
Cable specication
• Connectthepowercabletotheauxiliarycircuitbreaker.Ifeverypolefailstoconnecttothe
power supply, it must be incorporated in a wire with a contact opening of ≥3 mm.
• Useshieldcable(Category5;lessthan50pF/m)fornoisyenvironmentalsite.
Connecting the cable
Electrical work
(1) For electrical and earth works, comply with the ‘technical standards of electrical installations and the the ‘wiring
regulations of the Local wiring regulations.
(2)Tightentheterminalblockscrewtounder1.2N•m(12kgf•cm).
(3) Precautions when connecting terminal blocks of the indoor unit
Before connecting, make sure the connecting part of the terminal socket is facing upwards.
Upside down
The terminal
socketis damaged.
There is no ring
terminalto cover the wire.
There must be no space between the terminal and the screw when connected.
- Any remaining space may become are hazard due to overheating of the electrical contact.
The terminal socket
is upside down.
Either the screw is not fitted
properly or there is a space between
the screw and the ring terminal.
• Fortheterminalblockwiring,useawirewitharingterminalsocketonly.
Regular wires without a ring terminal socket may become a re hazard due to overheating of the electrical contact during
a wiring work.
1. Extend the assembly cable if necessary.
• Donotconnecttwoormoredierentcablestoextendthelength.
It may cause re.
Whenyouinstalltheunit,makerstrefrigerantconnectionsandthenelectricalconnections.
Connect the air conditioner to grounding system before performing the electrical connection.
If unit is uninstalled, rst disconnect electrical cables, then refrigerant connections.
If the outdoor unit is more than 4 or 5 meters away from the indoor unit, you must extend the cable. The maximum length of
the cable is 15(09/12) / 30(18/24) meters.
Model Power cable Interconnection cable Type GL
09/12
3G1.0mm
² H05VV-F 3G1.0mm² H07RN-F 20A
18
3G2.5mm
² H05VV-F 3G1.5mm² H07RN-F
25A
24
3G2.5mm
² H07RN-F 3G2.5mm² H07RN-F
English-35
INSTALLATION05