Indoor unit
Whereairowisnotblocked.
Wherecoolaircanbedistributedthroughouttheroom.
Install the refrigerant piping length and the height dierence of both indoor and outdoor units as indicated in the
installation diagram.
Wallthatpreventsvibrationandisstrongenoughtoholdtheproductweight.
Out of the direct sunlight .
1m or more away from the TV or radio (to prevent the screen from being distorted or noise from being generated).
As far away as possible from the uorescent and incandescent lights (so that the remote controller can be operated well).
A place where the air lter can be replaced easily.
Don't install directly above electronics equipment as leaking water may cause damage if not serviced. (eg. Computers, TV, etc).
Choosing the installation location
125 mm
or more
300 mm or more
125 mm
or more
600 mm
minimum
300 mm
minimum
300 mm
minimum
600 mm
minimum
'L' meters maximum
total pipe length
Wraptherefrigerantpipesandthedrainhose
with the absorbent pad and vinyl tape. Refer to
page 42 for further details.
You can select the direction of
draining (left or right).
'H' meters maximum total
pipe height
The appearance of the unit may be dierent from the diagram depending on the model.
Model L H
AJ18/21FCJ
50 15
AJ24/27HCJ
70 15
Makeatleastoneround:Itwillhelpreducenoiseandvibration.
'L' m as maximum pipe length
and 3 m as minimum pipe length.
(It will reduce noise and vibration)
Main power switch
A
B
C
D
English-30