Fixing the installation plate
You can select the direction of the drain hose depending on where you want to install the indoor unit. Therefore before xing
the installation plate to a wall or a window frame, you must determine the position of the 65mm hole through which the cable,
pipe and hose pass to connect the indoor unit to the outdoor unit.
Whenfacingthewall,thepipeandcablecanbeconnectedfromthe:
A
C
B
D
D
Direction of pipe
1. Determine the position of the pipe and drain hose hole as seen in the picture and drill the hole with an inner diameter
of 65mm so that it slants slightly downwards.
• Makesuretodrillonlyoneholeafterchoosingthe
direction of the pipe.
(Unit:mm)
Model A B C D
09/12
36 120 81 36
18/24
33 110 110 33
•Right(A)
•Left(B)
•Underside_right(C)
•Rear_rightorleft(D)
B
A
D
C
B
A
D
C
Pipe hole (Ø65 mm) Pipe hole (Ø65 mm)
Wall
<20mm
Plastic
Anchor
2. Fix the indoor unit.
If you x the indoor unit on a wall
(1) Fix the installation plate to the wall giving attention to the weight of the indoor unit.
If you x the indoor unit on a window frame
(1) Determine the positions of the wooden uprights to be attached to the window frame.
(2) Attach the wooden uprights to the window frame giving attention to the weight of the indoor unit.
(3) Attach the installation plate to the wooden upright using tapping screws.
If you x the indoor unit on a gypsum board
(1) Use stud nder to nd out locations of the studs.
(2) Fix the plate hanger on two studs.
• Ifyoumounttheplatetoaconcretewallusingplasticanchors,makesurethatgaps
between the wall and the plate, created by projected anchor, is less than 20mm.
• Searchforotherspotsiftherearelessthantwostuds,orthedistancebetweenthestudsaredierentfromthe
plate hanger.
• Fixtheinstallationplatewithoutincliningtooneside.
• Makesurethatawallcanwithstandtheweightoftheproduct.Ifyouinstalltheproductinaplacewhereitisnot
strong enough to withstand the product weight, the unit could fall and cause injury.