Checking before useOperation rangesThe table below indicates the temperature and humidity ranges the air conditioner can be operated within. Refer to
Main partsYour air conditioner may slightly look dierent from illustration shown above depending on your model.Checking the name of the partsDisplayA
Checking the remote controllerRemote controller buttons• Pointtheremotecontrollertowardstheremotecontrollerreceiveroftheindoorunit.• Wh
Remote controller display• Thesignalmaynotbereceivedwellofelectroniclightingstyleuorescentlampssuchasinverteruorescentlampsare i
Basic functionBasic operation is an operation mode that can be selected by pressing the Mode button. DryThe air conditioner in Dry mode acts like a de
Press the button to turn on the air conditioner.Press the button to set the operating mode.• EachtimeyoupresstheMode button, the mode will ch
Adjusting the air ow directionAir ow can be directed to your desired position.Vertical air owAir ow blades move up and down. Press the Vertical
Using the Fast functionUsing the Comfort functionYou can set the Fast function to provide powerful cooling.• FastfunctionisonlyavailableinCool
modeFor a comfortable sleep, the air conditioner will operate it Fall asleep Sound sleep Wakeupfrom mode.• SetOtimerin mode over 5 ho
Setting the On/O timerYou can set the air conditioner to turn on/o automatically at desired time. Setting On timer while the air conditioner is o /
Features of your new air conditioner2-step cooling2-step cooling function will quickly cool the room to reach the desired temperature and then it will
Combining On Timer and O TimerIf the air conditioner is on If the air conditioner is oPreset time on On timer is longer than O timerEx)Ontimer:
This function will produce positive ions and supply them into the airow. Quiet• TheVirusDoctor function can be selected whether the air condit
Cleaning the air conditionerCleaning the indoor unitCleaning the outdoor unit heat exchanger Wipethesurfaceoftheunitwithaslightlydampmicro
Removing the Air lterThere is a hole on the bottom right side of the lter. Put your nger in that hole to get a grip on the lter and slightly push
Cleaning the air conditionerReassembling the Air lter1. Put the lter on the main body and insert the hooks which are in the bottom of the Air lter
Maintaining the air conditionerIf the air conditioner will not be used for an extended period of time, dry the air conditioner to maintain it in best
TroubleshootingRefer to the following chart if the air conditioner operates abnormally. This may save time and unnecessary expenses.PROBLEM SOLUTIONTh
PROBLEM SOLUTIONFan speed adjustment is not working.• CheckifyouhaveselectedAuto/Dry/Turbo/ mode. In these mode, fan speed is set to Auto and y
Carefully follow the precautions listed below because they are essential to guarantee the safety of the equipment.•Alwaysdisconnecttheairconditi
After completing the installation, always carry out a functional test and provide the instructions on how to operate the air conditioner to the user
ContentsPreparationSafety precautions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Indoor unit Whereairowisnotblocked. Wherecoolaircanbedistributedthroughouttheroom. Install the refrigerant piping length and the he
Thefollowingaccessoriesaresuppliedwiththeairconditioner:• Thenumberofeachaccessoryisindicatedinparentheses.Accessories in the indoor
Fixing the installation plateYou can select the direction of the drain hose depending on where you want to install the indoor unit. Therefore before
Disassembling/Assembling the Cover panel for indoor unit installationIn order to install the indoor unit, you must disassemble the cover panel rst. P
Removing the hooks on the side Removing the hooks on the central part Caution (fragile) - Gently press the both side of the cover panel inwa
Connecting the assembly cableCable specication• Connectthepowercabletotheauxiliarycircuitbreaker.Ifeverypolefailstoconnecttothepow
2 . Open the cover panel.3 . Remove the screw securing the connector cover.4 . Pass the assembly cable through the rear of the indoor unit and conn
Installing and connecting the assembly pipe of the indoor unit1. Cut out the appropriate knock-out piece (A, B, C) on the rear of the indoor unit unl
Purging the indoor unit• TheremainingairintheRefrigerationcycle,whichcontainsmoisture,may cause malfunction on the compressor.• Alwaysc
Indoor outlet pipe Connecting pipeFlare nut5. Check if you ared the pipe correctly (see examples of incorrectly ared pipes below).6. Align the pip
Safety precautionsBefore using your new air conditioner, please read this manual thoroughly to ensure that you know how to safely and eciently operat
Installing and connecting the drain hose of the indoor unitThe drain hose must NOT slant upwards. The end of the drain hose must NOT be placed under
Changing direction of the drain hose• Thehosewillbexedpermanentlyintopositionafternishingtheinstallationandthegasleaktest.• Mak
Fixing the indoor unit in placeInsulationPipesPerform the following work on the area where gas leak test was done priory.After checking for gas leaks
Final check and trial operationTo complete the installation, perform the following checks and tests to ensure that the air conditioner operates correc
How to connect your extended power cables Items to prepare (compressor and insulation tape should be prepared by an installation technician.)1. A
Sub PCB installation(optional)(Wriedremotecontroller,centralremotecontrolleretc.)1. Turn the power o and take o the cover panel of the indoor
QUESTIONS OR COMMENTS?COUNTRY CALL OR VISIT US ONLINE AT SINGAPORE (65) 6568 6655 www.samsung.com
AR✴✴FSSSBWK SeriesAR✴✴FSSSCUR SeriesAir Conditioneruser & installation manualimagine the possibilitiesThank you for purchasing this Samsung produc
Do not install this appliance near a heater, inammable material. Do not install this appliance in a humid, oily or dusty location, in a location expo
Safety precautionsFOR POWER SUPPLYCAUTIONWhen not using the air conditioner for a long period of time or during a thunder/lightning storm, cut the pow
Do not insert your ngers or foreign substances into the outlet when the air conditioner is operating. Take special care that children do not injure
Safety precautionsFOR USINGCAUTIONDo not place objects or devices under the indoor unit. Water dripping from the indoor unit may result in fire or pr
FOR CLEANINGWARNINGDo not clean the appliance by spraying water directly onto it. Do not use benzene, thinner or alcohol to clean the appliance. Thi