5-20
● Quality
Recording resolution will be determined.
Choose one from Level 1(Low) to Level 8 (High). Level 8 supplies the best resolution
● Rate
Determines Frame Rate to be recorded. Frame Rate means the number of screen
recorded every second.
Set to 25ips, the system records too many screens per second and play continues
intermittently since recording is more detailed. This is appropriate for concentrated
monitoring zone setup.
25 ips/ 12.5 ips/ 8.33 ips/ 6.25 ips/ 5 ips/ 2.5 ips/ 1 ips
● PreAlarm
● PostAlarm
Records the situation until Alarm is issued.
Off : No recording
5sec/ 10sec/ 20sec/ 30sec : The recording time options before Alarm issue
Records the situation since Alarm is issued.
Off : No recording
5sec/ 10sec/ 20sec/ 30sec/1min/3min/5min/10min/20min :
To this, the recording time after Alarm issue is set.
Note
Note
[Monitor Out]
You are not allowed to set up “25ips” of Rate and Video sized “Full D1” simultane-
ously. The system does not support both at once.
Pre Alarm Section
Event occurred point of time
Post Alarm Section
Event occurred point of time