6.1.2.5 Sensor Test
- These Functions are considered to check the present state (normal or not) of the Sensors.
1. Press the "Menu Key", until finding "Sensors Test" message on the panel.
2. Press the "Select Key", when it's found.
3. Press the "Arrow keys" (< / >), until finding a suitable function.
4. Press the "Select Key", when it's found.
3. Touch a sensor you would like to test.
4. Confirm a message on the LCD window for the state of it.
Sub Menu Description Display(LCD)
Befor touching After touching
MP Tray Sensor After the tray 1 is gotten down, touch the sensor MP Tray Sensor Off MP Tray Sensor Oo
and confirm the message changed "Tray 1 Sensor Off"
to "Tray 1 Sensor On"
Tray1 Sensor After the tray 2 is pulled out, touch the sensor Tray 1 Sensor Off Tray 1 Sensor On
and confirm the message changed "Tray 2 Sensor Off"
to "Tray 2 Sensor On".
Tray2 Sensor After the tray 3 is pulled out, touch the sensor Tray 2 Sensor Off Tray 2 Sensor On
and confirm the message changed "Tray 3 Sensor Off"
to "Tray 3 Sensor On".
Duplex Sensor After the back cover is open, push a paper into the Duplex Sensor Off Duplex Sensor On
duplex path and confirm the message changed
"Duplex Sensor Off" to "Duplex Sensor On".
Cover Open After the cover is open, touch the sensor and confirm Cover Open Cover Close
Sensor the message changed "Cover Open" to " Cover Close"
Feed Sensor Touch the Feed sensor. Feed Off Feed On
Exit Sensor Touch the Feed sensor. Exit Off Exit On