33
Operating InstructionsOperating Instructions
32
- When “PRESET 3200K” is set, each Red and Blue
comes out in 3200°K.
- When “PRESET 5600K” is set, each RED and Blue
comes out in 5600°K.
- When “PRESET OFF (USER)--” is set, each Read
and Blue Gain can be adjusted by the user.
7) SYNC MODE
Move the cursor to “SYNC” and select the
“Power Sync (LINE---)/Internal Sync (INT)”
using right/left direction switch.
If the camera is set to INT (Internal Sync) mode
when monitoring in the Auto Switching mode with
more than one camera connected to a sequential
switcher, etc, the jump of the screen will occur each
time of screen switching.
To switch the screen gently without a jump, set the
camera to “L.L” and adjust the Vertical Sync Phase.
* However, L.L function can be used only when
using AC power. This setting is prohibited when
DC power is used. When DC power is used, only
INT is available.