Checking before use
Operation ranges
The table below indicates the temperature and humidity ranges the air
conditioner can be operated in. Refer to the table below for ecient use.
Maintaining your air conditioner
If the air conditioner operates in cooling mode for long period of time in high humidity area, dew may be formed.
Mode Indoor temperature Outdoor temperature Indoor humidity
Cooling
16 ˚C~32 ˚C 15 ˚C~43 ˚C Relative humidity 80% or less
Dry
18 ˚C~32 ˚C 15 ˚C~43 ˚C -
Internal protection via the unit control system
This internal protection operates if an internal fault occurs in the air conditioner.
Type Description
Against cold air
The internal fan will be switched o to prevent cold air when the heat pump is heating.
Defrost cycle
The internal fan will be switched o to defrost ice when the heat pump is heating.
Vertical air ow blade will be closed during defrost cycle and it will open again during
heating operation after defrost cycle.
Protect compressor
The air conditioner does not start operating immediately to help protect the outdoor
unit's compressor after it has been switched on.
• IftheheatpumpisoperatinginHeatmode,Defrostcycleisactuatedtohelpremovefrostfromanoutdoorunit
that may have deposited at low temperatures.
The internal fan is switched o automatically and restarted only after the defrost cycle is completed.
• OnlyHeatingmodelshavethisfunction:AR
✴✴
HP/JP
✴✴
series
UN_ME_BETTER_A3050_IB&IM_EN_DB68-05205A_UX.indd 10 24/02/2015 13:15:41