Disassembly
Samsung Electronics 4-27
There are 4 connectors to the SMPS. The power connector is +5V and +24V output from SMPS.
AC for fuser is AC output from SMPS to the fuser. And there are microswitches which are
attached to the upper frame and which are attached to the upper frame and which are shorted
when Top cover is closed, namely interlock Switches for +24V for HVPS, motor and for +5V for
Laser beam.
The Bracket Duplex Ass’y is located in the left upper side. Remove the screws and detach the
ass’y from the Frame.
In order to remove the connector of Solenoid, first remove Engine Controller Board.
Refer to Engine Controller Board disassembly (4-11)
+5V
+24V
AC Connector
Bracket Duplex Ass’y