- 30 -
1. PROTOCOL ID: 2, 15
1) Maker :
VICON HALF(2)/FULL(15)
2)DipSwitch:
Set 1,2,3,4 pin of SW704. (To Select Protocol)
VICON
HALF
Duplex
ON
OFF
SW704
12
34 5 6 78
VICON
FULL
Duplex
ON
OFF
SW704
12
34 5 6 78
※
Refer to SCC-C64XX User's Manual
SW704 5~6 : Baud Rate
Baud Rate SW704-5 SW704-6
19200BPS OFF OFF
9600BPS ON OFF
4800BPS OFF ON
※₁
600BPS ON ON
3) Function
VICON (VP8328, V1300X-DVC) SCC-C64XX
1 Pan/Tilt/Zoom/Focus/Iris Pan/Tilt/Zoom/Focus/Iris
2 RUN MODE : PP ENTER
→
#(1~89)
→
PP ENTER Go to Preset (1 ~ 89)
3 PGM MODE : PP ENTER
→
#(1~89)
→
PP ENTER Save Preset (1 ~ 89)
4 RUN MODE : PP ENTER
→
#(90)
→
PP ENTER Menu On/Off
5 RUN MODE : PP ENTER
→
#(91)
→
PP ENTER Menu Mode : ENTER Key
6 RUN MODE : PP ENTER
→
#(92)
→
PP ENTER Scan 1 On/Off
7
RUN MODE : PP ENTER
→
#(93)
→
PP ENTER or
RUN MODE : A/P
Auto Pan 1 On/Off
8 RUN MODE : PP ENTER
→
#(94)
→
PP ENTER Pattern1 On/Off
9 RUN MODE : PP ENTER
→
#(95)
→
PP ENTER Pattern 2 On/Off
10 RUN MODE : PP ENTER
→
#(96)
→
PP ENTER Pattern 3 On/Off
11 RUN MODE : PP ENTER
→
#(98)
→
PP ENTER Alarm Reset
12 RUN MODE : PP ENTER
→
#(99)
→
PP ENTER Camera Reset
13 Joystick Up Menu Mode:
↑
Key
14 Joystick Down Menu Mode:
↓
Key
15 Joystick Left Menu Mode:
←
Key
16 Joystick Right Menu Mode:
→
Key
※₁
600 BPS is recommended when you install more than 128 cameras.