1 - 9
1.2.6.4 Data Character Formats
Data bits 5, 6, 7 or 8 bits/character
Parity Odd, even or none
Stop bits 1 or 2
1.2.6.5 Baud Rates
Internal baud rates can be selected from 150 to 115,200 baud. Standard rates are: 150, 300, 600, 1200,
2.4 K, 4.8 K, 7.2K, 9.6 K, 19.2 K, 38.4 K, 57.6 K, 76.8K and 115.2K. Baud rate accuracy is ±0.02
%. Other internal baud rates are programmable up to 153.6 Kbaud by specifying the baud rate
generator time constant. Combined baud rate for a channel pair (channels 1 & 2 or channels 3 & 4)
should not exceed 230.4 Kbaud.
1.2.6.6 X-On/X-Off Protocol
X-on/X-off protocol for flow control can be separately enabled for each serial channel.
1.2.6.7 Serial Buffers
Each serial interface includes the following data buffers:
Buffers Standard Units Extended RAM Units
Transmit 4,092 bytes 16,380 bytes
Trigger Buffers 4 @ 512 bytes 8 @ 1,024 bytes
Receive Buffer 4,092 bytes 16,380 bytes
1.2.6.8 Termination Resistor Network
For RS-422/RS-485 applications, the VXI-5534 serial interfaces can be configured to switch a
termination resistor network across the Tx and Rx signal pairs by a VXIbus command. The
termination resistor networks are mounted on plug-in headers. The standard termination network is
a 220 ohm load with 1 Kohm pullup and pulldown resistors to hold undriven Tx/Rx lines at +2.7 and
+2.2 volts. VXI-5534 channels must be configured in pairs as RS-422/RS-485 interfaces to use the
resistor termination networks.