Samsung SMO-150QP Especificaciones

Busca en linea o descarga Especificaciones para Los Sistemas De Control De Acceso De Seguridad Samsung SMO-150QP. Samsung SMO-150QP Specifications Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 67
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
Artisan Technology Group is your source for quality
new and certied-used/pre-owned equipment
FAST SHIPPING AND
DELIVERY
TENS OF THOUSANDS OF
IN-STOCK ITEMS
EQUIPMENT DEMOS
HUNDREDS OF
MANUFACTURERS
SUPPORTED
LEASING/MONTHLY
RENTALS
ITAR CERTIFIED
SECURE ASSET SOLUTIONS
SERVICE CENTER REPAIRS
Experienced engineers and technicians on staff
at our full-service, in-house repair center
WE BUY USED EQUIPMENT
Sell your excess, underutilized, and idle used equipment
We also offer credit for buy-backs and trade-ins
www.artisantg.com/WeBuyEquipment
REMOTE INSPECTION
Remotely inspect equipment before purchasing with
our interactive website at www.instraview.com
LOOKING FOR MORE INFORMATION?
Visit us on the web at www.artisantg.com for more
information on price quotations, drivers, technical
specications, manuals, and documentation
Contact us: (888) 88-SOURCE | sales@artisantg.com | www.artisantg.com
SM
View
Instra
Vista de pagina 0
1 2 3 4 5 6 ... 66 67

Indice de contenidos

Pagina 1 -

Artisan Technology Group is your source for quality new and certied-used/pre-owned equipment• FAST SHIPPING AND DELIVERY• TENS OF THOUSANDS OF IN-S

Pagina 2 - VXI-5534

1 - 11Specifications1.1 DESCRIPTION1.1.1 VXI-5534 Quad Serial Interface ModuleThe VXI-5534 Quad Serial Interface Module provides four separate serial

Pagina 3 - Instruction Manual

1 - 21.1.2 VXIbus Description1.1.2.1 VXIbus ObjectivesThe goal of the VXIbus Consortium is to create an open industry standard for modular instruments

Pagina 4

1 - 31.1.2.3 VXIbus System ConfigurationsVXIbus systems utilize a chassis with a backplane and a common power supply. Modules plug intothe chassis fr

Pagina 5 - Contents

1 - 4TABLE 1-1 VXIBUS GLOSSARYCommander: A VXIbus device that has VME bus master capability and may have VXIbus servants under it inthe system hi

Pagina 6

1 - 51.2 DETAIL SPECIFICATIONSThe following specifications apply in general to all VXI-5534 modules.1.2.1 Model Number DesignationVXI-5534 -X General

Pagina 7

1 - 61.2.3 VXIbus Word Serial CommandsThe VXI-5534 supports the following word serial commands:Standard I4 Word Serial CommandsAbort Normal operationB

Pagina 8

1 - 71.2.5 VXIbus IEEE 488.2 Common CommandsThe VXI-5534 supports the VXIbus IEEE 488.2 Common Commands listed in Table 1-2 to performfunctions such

Pagina 9

1 - 81.2.6 Serial InterfacesThe VXI-5534 provides four serial interfaces for asynchronous communication with externaldevices. Each interface supports

Pagina 10 - Specifications

1 - 91.2.6.4 Data Character FormatsData bits 5, 6, 7 or 8 bits/characterParity Odd, even or noneStop bits 1 or 21.2.6.5 Baud RatesInternal baud rates

Pagina 11

1 - 10 1.2.7 Configuration CommandsThe VXI-5534 uses the commands listed in Table 1-3 to configure its serial interfaces. Configurationsettings can

Pagina 12

1 - 1VXI-5534ICS MODEL VXI-5534 QUAD SERIAL INTERFACE MODULEMODEL VXI-5534VXI Quad Serial Interface ModuleInstruction ManualArtisan Technology G

Pagina 13 - TABLE 1-1 VXIBUS GLOSSARY

1 - 111.2.8 Front Panel IndicatorThe VXI-5534 has a four character alpha numeric display on the front panel which displays status,logical device addre

Pagina 14

2 - 12Installation2.1 UNPACKING AND INSPECTIONIf shipping carton or instrument is damaged, call carrier immediately and inspect the contents fordamage

Pagina 15

2 - 2Figure 2-1 Address Switch LocationFigure 2-2 Address Switch LayoutNote - White blocks show switch set to logical address 16 (10 HEX)Addre

Pagina 16

2 - 32.3 ADDRESS SWITCH SETTINGSThe VXI-5534 has an internal address switch located on the rear of the module between P1 and P2for setting the VXI-553

Pagina 17

2 - 42.3.3 Checking the VXI-5534's Logical Device AddressTo check the address setting of the module, press the DISPLAY MODE button with a small t

Pagina 18

2 - 52.4 SERIAL INTERFACEThe VXI-5534 has four 9 pin DE-9P connectors with lock studs that independently provide eitherRS-232, RS-423 or RS-422/RS-485

Pagina 19

2 - 6Figure 2-4 VXI-5534 Jumper Locations (Factory Settings)Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE |

Pagina 20

2 - 72.4.2 RS-423 Signal Connections and SetupRS-423 signal levels are set by moving a pair of jumpers per serial channel to a lower voltage positiona

Pagina 21 - Installation

2 - 82.4.3 RS-422 and RS-485 Signal Connections and TerminationsWhen RS-422/RS-485 signals are selected, the signals change from single-ended, bipolar

Pagina 22 - 2 4 2 6

3 - 13Operation and Programming3.1 INTRODUCTIONThis section describes how to program and use the VXI-5534. This includes directions for using theFron

Pagina 23

MODEL VXI-5534VXI Quad Serial Interface ModuleInstruction Manual473 Los Coches Street, Milpitas, CA 95035 Publication Number 120134Phone (408) 263-5

Pagina 24

3 - 2TABLE 3-1 VXI-5534 DISPLAY MODESDisplay DescriptionModeNorm The Norm or normal mode selects the power on messages listed in Table 3-2A.Extd T

Pagina 25 - 25 Pin Connector

3 - 33.2.2 Display Mode ButtonThe Display Mode Button is a recessed bush button located below the display as shown in figure3-1. The button selec

Pagina 26

3 - 4TABLE 3-2A VXI-5534 NORMAL MODE MESSAGESDisplay Meaning5534 Power on ID messageBgNn Begin normal operation for channel nE2Sv Data written t

Pagina 27

3 - 53.3 GENERAL OPERATING INSTRUCTIONSNew users and programmers not experienced with the VXI-5534 should read Section 3 of thismanual. The few minut

Pagina 28

3 - 63.3.3 Configuring the Serial InterfaceIf this is the initial use of the VXI-5534, its interfaces should be configured at this time. Table 3-3lis

Pagina 29 - Operation and Programming

3 - 73.4 VXI-5534 CONFIGURATION COMMANDSThe VXI-5534 accepts SCPI like commands to configure its serial interfaces and its operation. Thecommands a

Pagina 30 - Display Description

3 - 8TABLE 3-3 VXI-5534 CONFIGURATION COMMAND LISTCommand Default DescriptionBAUD <numeric> 9600 Sets baud rate. Allowed values are: 150,300

Pagina 31 - Button

3 - 9TABLE 3-3 VXI-5534 CONFIGURATION COMMAND LISTCommand Default DescriptionPARITY <alpha> NONE Enables parity generation and checking. Al

Pagina 32

3 - 103.5 PROGRAMMING GUIDELINES3.5.1 Setting the Baud RateThe majority of baud rates can be entered with BAUD command as shown in Table 3-3. Nonstan

Pagina 33

3 - 113.5.2 Sending DataThe easiest way to transmit data is to simply address the desired serial channel and send it the data.Use the Word Serial Data

Pagina 34

LIMITED WARRANTYWithin 12 months of delivery, ICS Electronics will repair or replace this product, at our option, if any part is found tobe defective

Pagina 35 - BAUD 9600; BITS 8; CONFIG?

3 - 123.5.4 Receiving DataThe serial interface always inputs data in the Data Mode as long as the control lines are in their highstate and there is ro

Pagina 36 - Command Default Description

3 - 133.5.5 Reading the VXI-5534's Status ByteThere are several ways the user can test the VXI-5534 to see if there is data in the receive buffer

Pagina 37

3 - 143.5.7 Controlling the VXI-5534 with Multi-Tasking Operating SystemsOutputting data to the VXI-5534 from a task in a Multi-Tasking environment do

Pagina 38

3 - 153.6 488.2 COMPLIANCE3.6.1 488.2 Common CommandsThe VXI-5534 responds to all of the required IEEE-488.2 common commands. The 488.2commands may

Pagina 39

3 - 163.6.2 488.2 Status Reporting StructureEach serial channel has its own IEEE-488.2 Status Reporting Structure as shown in Figure 3-3. TheVXI-553

Pagina 40 - the data buffer

3 - 17TABLE 3-5 IEEE 488.2 COMMAND LISTFactoryCommand Setting 488.2 Function *CLS - Clears all Event Registers and updates Status Byte register.

Pagina 41

3 - 183.7 VXI WORD SERIAL COMMANDSVXIbus systems use Word Serial Commands for handshaking data, controlling and querying VXIdevices. Word Serial Comm

Pagina 42

3 - 19 021B HEX would set buffer 1 to be triggered on TTLTriger line #3TABLE 3-6 VXI-5534 WORD SERIAL COMMAND LISTCommand Hex FunctionCodeAbort N

Pagina 43 - Output Queue

3 - 20Read Handler Line # 8Cxx Determines which IRQ line a handler is connected to.Read Handlers # C7FF Determines the number of Interrupt Handlers in

Pagina 44

4-14Theory of Operation4.1 BLOCK DIAGRAM DESCRIPTIONThe Block Diagram for the VXI-5534 Quad Serial Interface Module is shown in Figure 4-1. TheVXIbus

Pagina 45

iContents1 SPECIFICATIONS ... 1-11.1 DESCRIPTION .

Pagina 46

4-2Figure 4-1 VXI-5534 Block DiagramSLAVE 2 BUSEPROMRAMBUSARBITRATIONLOGICRS-232RS-422RS-485RS-232RS-422RS-485S/PSLAVE 2µPCHANNEL 4SERIALINTERFACE

Pagina 47

4-34.3 SLAVE PROCESSORSEach slave processor has its own EPROM and RAM. The EPROM provides program storage andthe RAM stores the received and transmit

Pagina 48

5-15Maintenance5.1 INTRODUCTIONThis section describes the maintenance, troubleshooting and repair procedures for the VXI-5534Interface card. The VXI-

Pagina 49 - Theory of Operation

5-2Table 5-1 TROUBLESHOOTING GUIDE - error messagesError Messages Definitions ActionER01 VXI EPROM check sum error Replace the VXI processor E

Pagina 50

5-3Table 5-1 TROUBLESHOOTING GUIDE - error messages cont'dError Messages Definitions ActionER26 VXI → Ser 4 RAM buffer error Try replacin

Pagina 51

5-4TABLE 5-2 TROUBLESHOOTING GUIDE - User Problems cont'dProblem Possible Cause ActionFor half-duplex systems, try reversing the wires.Bau

Pagina 52 - Maintenance

5-55.3 RETURNING FOR FACTORY SERVICEWhen returning a VXI-5534 board assembly or other products to ICS for repair, it is necessary to gothrough the fol

Pagina 53

6-1Parts List and Location6.1 INTRODUCTIONThis section contains all information necessary to locate, identify, and order parts. The listing of partsa

Pagina 54

6-2TABLE 6-1 LIST OF MANUFACTURERS BY ABBREVIATIONCode Company Name LocationABC Allen Bradley Milwaukee, WIACT Advanced Components TechRedwood City,

Pagina 55

6-3TABLE 6-1 LIST OF MANUFACTURERS BY ABBREVIATION (CONT.)HIT Hitachi Toyko, JapanHOL Holmberg Electronics Corp. Inman, SCHP Hewlett-Packard Palo Alt

Pagina 56

ii1.2.7 Configuration Commands ... 1-101.2.8 Front Panel Indicator ...

Pagina 57 - Parts List and Location

6-4TABLE 6-1 LIST OF MANUFACTURERS BY ABBREVIATION (CONT.)Code Company Name LocationCode Company Name LocationRUS Russell Industries, Inc. Oceanside,

Pagina 58

6-56.3 PARTS LISTSThe parts list tables contains both the ICS Electronics Corporation stock numbers and the manufacturers’true part numbers where appl

Pagina 59

6-6TABLE 6-2 VXI-5534 RECOMMENDED SPARE PARTSMFGRLN# PART# QTY DESCRIPTION REF-DES MFGR PART #28 790189-16 1 IC MPU Z180 U33;38;67 ZIL Z8S18016V

Pagina 60

6-71 114566 1 PCB VXI-5534 A12 590000 95 Cap dip .01uF 50V C1-68;C70-96 AVX MD015E103AZAA3 535222 1 Cap Mono TS .0022 uF 50V C69 CNT CW15C222K4 521686

Pagina 61

6-8Figure 6-1 VXI-5534 Component LayoutArtisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Pagina 62

6-944 792130 2 IC RAM 1K x 8 dual port U62;63 AMD AM2130-10PC45 776264 1 IC RAM 8K x 8 U64 FUJ MB8464A-8046 792816-15 1 IC EEPROM 2K x 8 U66 SAM KM28C

Pagina 63

7-17Drawings, Diagrams, Wire ListsThis section includes the following figures and table:PageFigure 7-1 VXI-5534 Logic Diagrams 7-2Artisan Technology G

Pagina 64

Artisan Technology Group is your source for quality new and certied-used/pre-owned equipment• FAST SHIPPING AND DELIVERY• TENS OF THOUSANDS OF IN-S

Pagina 65

iii3.5 PROGRAMMING GUIDELINES ... 3-103.5.1 Setting the Baud Rate ...

Pagina 66

iv6 PARTS LIST AND LOCATION ...... 6-16.1 INTRODUCTION ...

Pagina 67

vTABLES1-1 VXIBUS GLOSSARY ......................... 1-41-2 VXIBUS IEEE 488

Comentarios a estos manuales

Sin comentarios