Samsung MWR-WE00 Especificaciones Pagina 4

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 13
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 3
S-inverter
44 <<<
>>>
45
S-inverter
Console
Optional Accessories Standard Accessories
Individual
Controllers
MWR-WE00
Wireless Remote
Controllers
Notes
1) Capacities are based on the following conditions.
Cooling : - Indoor Temperature 27
°C
DB/ 19
°C
WB
- Outdoor Temperature 35
°C
DB/ 19
°C
WB
- Interconnecting Piping Length [ 7.0kW : 5.0m, 9.0kW : 7.5m]
- Level Difference of Zero
Heating : - Indoor Temperature 20
°C
DB/ 15
°C
WB
- Outdoor Temperature 7
°C
DB/ 6
°C
WB
- Interconnecting Piping Length [ 7.0kW : 5.0m, 9.0kW : 7.5m]
- Level Difference of Zero
2) Capacities are Net Capacities.
3) Product Specifications in the Publication can be changed without a prior notice. Because there is always an ongoing improvement on our product.
* Specifications are subject to change without prior notice for product improvement.
Indoor Unit
Outdoor Unit
JH026EAV1
UH026EAV1
Capacity (Min./Standard/Max.)
Power Input (Min./Standard/Max.)
E.E.R
Running Current
(Min./Standard/Max.)
Piping Connection
Power Supply
Indoor Unit
Model
Fan Type
Air Flow Rate
Set
Sound Pressure Level
Indoor Filter(Catechin, Deodorizing)
Outdoor Unit
Model
Compressor
Refrigerant
Set
Sound Pressure Level
Temperature Range
Quantity of Ref.
Extension Length (total)
Extension Length (elevation)
Standard
Additional Ref.
Model
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Watts
Watts
Watts
Watts
W/W
W/W
Amps
Amps
mm (inch)
mm (inch)
Ø/V/Hz
m
3
/min
mm
mm
kg
dB(A)
mm
mm
kg
dB(A)
°C
°C
g
m
m
m
g/m
980/2,600/3,500
950/3,500/4,700
240/670/1,050
220/970/1,300
3.88(A)
3.93(A)
1.6/3.3/5.0
1.4/4.7/6.3
6.35(1/4)
9.52(3/8)
1/220~240/50
JH026EAV1
Turbo Fan
8.1
720X620X199
810X710X295
14.5/18.5
38/23
Default
UH026EAV1
SINGLE BLDC
R410A
790X548X285
938X610X382
35.5/38
47
-10~43
-15~24
950
20
15
5
0
JH035EAV1
UH035EAV1
990/3,500/4,200
990/4,000/5,000
270/1,090/1,350
240/1,108/1,350
3.21(A)
3.63(A)
2.0/5.2/6.2
1.6/5.3/6.6
6.35(1/4)
9.52(3/8)
1/220~240/50
JH035EAV1
Turbo Fan
9
720X620X199
810X710X295
14.5/18.5
39/24
Default
UH035EAV1
SINGLE BLDC
R410A
790X548X285
938X610X382
35.5/38
47
-10~43
-15~24
950
20
15
5
0
JH052EAV1
UH052EAV1
1,200/5,000/6,000
1,400/5,600/8,200
390/1,560/2,030
330/1,553/2,900
3.21(A)
3.61(A)
2.0/7.8/9.2
1.7/7.8/13.0
6.35(1/4)
12.7(1/2)
1/220~240/50
JH052EAV1
Turbo Fan
11.5
720X620X199
810X710X295
16/20.3
44/25
Default
UH052EAV1
SINGLE BLDC
R410A
880X638X310
1,023X704X413
52/56
55
-15~43
-15~24
1,450
50
30
5
30
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Liquid
Gas
High
WxHxD
WxHxD
High/Low
Type
WxHxD
WxHxD
Cooling
Heating
WirelessWireless
WirelessWireless
INTERIORINTERIOR
DESIGNDESIGN
INTERIORINTERIOR
DESIGNDESIGN
BACTERIABACTERIA
BACTERIABACTERIA
Flexible PipeFlexible Pipe
InstallationInstallation
Flexible PipeFlexible Pipe
InstallationInstallation
AUTOAUTO
AUTOAUTO
Ceiling
Optional Accessories Standard Accessories
Individual
Controllers
MR-CH01
Notes
1) Capacities are based on the following conditions.
Cooling : - Indoor Temperature 27
°C
DB/ 19
°C
WB
- Outdoor Temperature 35
°C
DB/ 19
°C
WB
- Interconnecting Piping Length [ 7.0kW : 5.0m, 9.0kW : 7.5m]
- Level Difference of Zero
Heating : - Indoor Temperature 20
°C
DB/ 15
°C
WB
- Outdoor Temperature 7
°C
DB/ 6
°C
WB
- Interconnecting Piping Length [ 7.0kW : 5.0m, 9.0kW : 7.5m]
- Level Difference of Zero
2) Capacities are Net Capacities.
3) Product Specifications in the Publication can be changed without a prior notice. Because there is always an ongoing improvement on our product.
* Specifications are subject to change without prior notice for product improvement.
Wireless Remote
Controllers
Indoor Unit
Outdoor Unit
FH052EAV1
UH052EAV1
Capacity (Min./Standard/Max.)
Power Input (Min./Standard/Max.)
E.E.R
Running Current
(Min./Standard/Max.)
Piping Connection
Power Supply
Indoor Unit
Model
Fan Type
Air Flow Rate
Set
Sound Pressure Level
Indoor Filter(Catechin, Deodorizing)
Outdoor Unit
Model
Compressor
Refrigerant
Set
Sound Pressure Level
Temperature Range
Quantity of Ref.
Extension Length (total)
Extension Length (elevation)
Standard
Additional Ref.
Model
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Dimension (Net)
Dimension (Gross)
Weight (Net/Gross)
Watts
Watts
Watts
Watts
W/W
W/W
Amps
Amps
mm (inch)
mm (inch)
Ø/V/Hz
m
3
/min
mm
mm
kg
dB(A)
mm
mm
kg
dB(A)
°C
°C
g
m
m
m
g/m
1,700/5,000/5,600
1,700/6,000/8,000
480/1,660/1,900
430/1,870/3,050
3.01(B)
3.21(C)
2.8/7.8/9.0
2.4/8.8/14.5
6.35(1/4)
12.7(1/2)
1/220-240/50
FH052EAV1
Sirocco fan
14.5
1,000X200X650
1,074X294X726
22/26
38/32
default
UH052EAV1
TWIN BLDC
R410A
880X638X310
1,023X704X413
50/54
49
-15~43
-20~24
1,450
50
30
5
30
FH070EAV1
UH070EAV2
2,000/7,100/8,000
2,000/8,000/10,500
610/2,520/2,900
580/2,750/3,700
2.82(C)
2.81(D)
3.0/11.5/13.0
2.9/12.5/17.0
6.35(1/4)
15.88(5/8)
1/220-240/50
FH070EAV1
Sirocco fan
16.0
1,000X200X650
1,074X294X726
22/26
41/36
default
UH070EAV2
TWIN BLDC
R410A
880X798X310
1,038X861X413
57/63
50
-15~43
-20~24
1,900
50
30
5
30
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Liquid
Gas
High
WxHxD
WxHxD
High/Low
Type
WxHxD
WxHxD
Cooling
Heating
WirelessWireless
WirelessWireless
INTERIORINTERIOR
DESIGNDESIGN
INTERIORINTERIOR
DESIGNDESIGN
BACTERIABACTERIA
BACTERIABACTERIA
Flexible PipeFlexible Pipe
InstallationInstallation
Flexible PipeFlexible Pipe
InstallationInstallation
AUTOAUTO
AUTOAUTO
MWR-WH00
MWR-WE00
MWR-WH00
2010 Samsung Ceiling Air Conditioners
INDOOR UNITS - SPECIFICATION
Vista de pagina 3
1 2 3 4 5 6 7 8 9 ... 12 13

Comentarios a estos manuales

Sin comentarios