Samsung SCX-4x24 Series Manual de servicio Pagina 80

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 80
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 79
Alignment & Troubleshooting
Service Manual
4-80
Samsung Electronics
2) Defective Image Quality of PC Scan
Description : The image PC scanned is not clear or bad.
1. Check the waveform form
by performing a CIS
test in 7(&+0RGH
If the CIS waveform form is
abnormal, try to replace the CIS
Ass'y.
If the resolution is set to low, let
the user be acquainted with the
using method well.
2. Check if the resolution is
set too low in PC Scan options.
(Refer to User's Manual.)