93
Problem Solution
Program does not run
Check if the PC (or server) runs other application programs. By running
multiple programs on the same a PC (or server), they may affect PC
performance. It is recommended to close all other application programs and run
SNM-64S/P only.
Check if USB dongle key is attached to the PC when you are running
SNM-64P.
Previous settings
disappear when re-install
the program
Confirm if the DB files are overwritten during the installation process. If
overwrite option is selected during the process, it is necessary to recover the
original DB files.
※ In the SNM-64S/P folder, there are MSetup(old)~.mdb files. Remove ‘(old)’
out of the name, and the previous settings are recovered.
‘Site Tree’ does not
display camera list after
registering a device
Check if the camera is selected in ‘Device Manager’ after registering login
information. It is necessary to compose the site tree after registering device.
Only the selected camera(s) in the ‘Site Manager’ appear under site tree when
the program runs.
Check if you logged in the program with other user ID. SNM-64S/P brings up
the corresponding settings for each user.
'Instant Player’ button is
not activated or does not
function
Check if the selected event or alarm is from DVR. ‘Instant Player’ is compatible
with DVR/Network Recorder only, and it is not supported with network camera
or video server.
Camera OSD button does
not function
Camera can be controlled only when connected to the RS-485’s configuration
communication terminal.
‘Original Size’ button is
not activated
‘Original Size’ menu is available only in single-channel mode.
Device is not listed in the
search list during device
registration
Check if the device is powered properly.
Open MS-DOS window to check whether device is connected to the network.
Check if you run ‘SNM-64S’ and ‘SNM-64P’ at the same time. If so, a device
responds to a program that runs earlier.
‘Record’ button is not
activated
Check if you selected a video screen from DVR. Record menu is compatible
with network camera and video server and is not compatible with DVR.
Programmed ‘Action’
does not perform against
alarm
Check the time schedule of the alarm processing. Alarm is processed only for
the scheduled time and the same signal is disregarded for the other time.
Check the time schedule of the action. Action does perform only for the
scheduled time.
Check if ‘For video-displayed devices mode’ in ‘Event Reception’ menu. Under
‘For video-displayed devices’ mode, actions cannot perform even during the
scheduled time. Only the logs are displayed in the list pane.
Image transferred to FTP
or by E-mail cannot be
viewed
Check if an image is captured properly with ‘Snapshot’ menu. Check if the
stored snapshot image is proper or not. The snapshot image is firstly archived
and then transmitted to FTP server or e-mailed.
Comentarios a estos manuales